Supply of Switch Off Timer For Geysers With Selectable Option Of 01 To 60 Minutes Duration And Maxim Um Load Capacity Of 3.0 Kw Suitable To Work On 230 Volts, 50 Hz Ac Single Phase Supply Housed In Enclosur E Made Of Crca Sheet 01 Mm Thick Of Dimensions 180 Mm * 160 Mm * 120 Mm. Detailed Technical Specific Ation As Follows: A. Switch Off Timer/Interval Timer: Switch Off Timer Unit Shall Have Manual Selectio N Of Switch Off Time Range Of 0-60 Minutes With Following Features: 1. Accuracy Setting +/- 5% Of Fs, 2. Res Et: On Interruption Of Power, Reset Time < 100 Ms 3. Output Contact: Dpdt 2 C/O 4. Contact Rating: 5A @ 230 Volts Ac 50 Hz, 5. Timer Range: 0-60 Min, 6. Supply Voltage: 120-240 V Ac, 7. Power Consumption: 2 V A Max, 8. Mounting: Din Rail/Back Panel, B. Switchgears: All Switch Gears Used In Panel Shall Be Approve D By Railways And Supplier Has To Take Prior Approval Before Manufacturing 1. 25 A 3-Pole Power Contactor- 01 No. At Load Side, 2. 25 A Dp Mcb- 01 No At Incoming Side 3. Led Indicator 4. 15 A Socket, 5. 1 5 A Plug With 1 Metre 3 Core 2.5 Sq.Mm Copper Cable, 6. 4 Sq.Mm Cable Shall Be Used For Wiring The Above Items, C. Panel Board: The Panel Board Will Be Cubicle Type, Wall Mounting Design, The Panel Will Be Fabri Cated Out Of 1 Mm Thick Crca Sheet Steel Of Dimensions 180Mm*160Mm*120Mm. The Enclosure Will Be Pre -Treated As Per 7 Tanks Process And Finished With Powder Coating. The Degree Protection Of The Panel Is Ip42 D. General Requirements: 1. The Unit Shall Be Suitable For Wall Mounting/ Hanging Type, 2. The Unit Sho Uld Be Compact And Robust, 3. The Unit Should Have Protected Against Open Circuit And Short Circuit For The Cables And Circuit Used, The Design Shall Be Modular So That Only Defective Part Needs To Be Replaced War Ranty Period: 12 Months After The Date Of Delivery
Supply And Installation Of Ms Fabricated Hinged Type Cubicle Panel Board Mccb Panel Distribution Box Made Of 14 Swg, Ms Sheet Duly Powder Coated. Make: - L&T/Abb/C&S/Siemens. Specification As Per D Rg. No: - Trs/Hwh/El-872/24 Attached. Warranty Period: 30 Months After The Date Of Delivery
Dnit For Running Rate Contract For Providing And Fixing Following Rating And Breaking Capacity And Pole Mccb With Thermomagnetic Release And Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel, Making Connecti
Armo Various Electrical And Mechanical Services At District Court, Rohini, Sh Sitc Of Cubicle Panel Board For Augmentation Of General Power Supply For Various Floors In Lawyers Chamber
Supply Of 1.5 Tr 5Star Inverter Type Split Ac Q3, 2.0 Tr 5 Star Inverter Type Split Ac Q3, 4.0 Kv Voltage Stablizer Q3, 5 Kva Voltgae Stblizer Q3, Ms Angle Stand For Outdoor Unit Of Split A. C Q3, Extra Refrigerant Piping With Insulation For Split Air Conditioner Q3, Control Cable Between Indoor To Outdoor Unit 4 Core Copper Q3, Pvc Drain Pipe Q3, Sheet Steel Enclosure Flush/ Surface 20A 2 Pin Metal Clad Scraping Earth Plug For Ac With Mcb Cat A Q3, Surface/ Flush Mounting 4 Ways V Tpn Distribution Board With Additional Metal Door Without Mccb Q3, 80 To 100 Amp 4 Pole Mccb 16Ka Thermal Magnetic Release. Q3, 6 To 32A Spmcb 10Ka C Curve Q3, Submain Fr Pvc Insulated Copper Cond. 6 Sqmm 2 Wire In Pvc Conduit Q3, 150 Sq Mm 3-1/2 Core Armoured Cable Q3, 25 Sqmm 3-1/2 Core Armoured Cable Q3, Cable Gland 150 Sqmm 3-1/2 Core Q3, Cable Gland 25 Sqmm 3-1/2 Core Q3, Cable Lug 150 Sqmm Q3, Cable Lug 95 Sqmm Q3, Cable Lug 25 Sqmm Q3, Cable Lug 16 Sqmm Q3, 200 A Mccb - 1 Nos. Outgoing 100 A Mccb - 1 Nos & 63 Amp Mccb - 3 Nos. Cat B Panel Cubicle Type Q3, Danger Board Fabricated From 10 Gauge M. S. Sheet Q3, Safe Earthing Electrode T-19 Q3, G. I. Strip Q3, Fire Extinguisher Q3
Supply Installation Testing And Commissioning Of Mv Cubicle Type Pedestal Mounted Panel Board Panel Size Height 182 Cm Length 340 Cm Width 60 Cm With Backdoor Open., Incomer Acb 800 Amps Tp And Microprocessor Based Edo Acb, Incomer Digital Volt And Ammeter With Suitable Selector Switch, Incomer Acb Manual On Off Push Button Switch, Incomer Ryb Phase Indicators, Outgoing Channel No 1 For Fully Automatic Star Delta Starter 415 V 50 Hz 3 Phase 125 Kw 735 Rpm For Dewatering Pump Prime Mover Motor 400 Amps 3 Pole Mccb 50 Ka Tm, Outgoing Channel No 1 Digital Volt And Ammeter With Selector Switch, Outgoing Channel No 1 Ryb Phase Indicator, Outgoing Channel No 1 Fully Automatic Star Delta Starter With Olp Phase Failure And E F Relay, Outgoing Channel No 2 Fully Automatic Star Delta Starter 415 V 50 Hz 3 Phase 125Kw 735 Rpm For Dewatering Pump Prime Mover Motor 400 Amps 3 Pole Mccb 50 Ka Tm, Outgoing Channel No 2 Digital Volt And Ammeter With Selector Switch, Outgoing Channel No 2 Ryb Phase Indicator, Outgoing Channel 2 Fully Automatic Star Delta Starter With Olp Phase Failure And E F Relay, Outgoing Channel No 3 Fully Automatic Star Delta Starter 415 V, 50 Hz 3 Phase 11Kw 15 Hp 1440 Rpm For Auxiliary Pump Prime Mover Motor 32 Amps 3 Pole Mccb 25 Ka Tm, Outgoing Channel No 3 Fully Automatic Star Delta Starter With Olp Phase Failure And E F Relay, Outgoing Channel No 4 Fully Automatic Star Delta Starter 415 V 50 Hz 3 Phase 11Kw 15 Hp 1440 Rpm For Auxiliary Pump Prime Mover Motor 32 Amps 3 Pole Mccb 25 Ka Tm, Outgoing Channel No 4 Fully Automatic Star Delta Starter With Olp Phase Failure And E F Relay, Outgoing Channel No 5 Dol Starter 415 V 50 Hz 3 Phase 3 7Kw 5 Hp 1440 Rpm For Pump Prime Mover Motor With Olp 32 Or 16 Amps 3 Pole Mcb, Outgoing Channel No 5 Dol Starter With Olp Phase Failure And E F Relay, Outgoing Channel No 6 Dol Starter 415 V 50 Hz 3 Phase 3.7Kw 5 Hp 1440 Rpm For Pump Prime Mover Motor 32 Or 16 Amps 3 Pole Mcb, Outgoing Channel No 6 Dol Starter With Olp Phase Failure And E Or F Relay, 100 A 4 Pole Mccb Tm 36 Ka For Eot Crane Or Spare, Tp And N Mcb 32 Amps 16Ka, 10 A Sp Mcb 10 Ka, Supply Of The Material And Installation Of Maintenance Free Earthing System
Providing New Cubicle Mv Panel Board With 250A Sdfu 100A Sdfu Along With 250Amps Change Over Switch At Central Office Building In Premises Of Tangedco Campus
Fabrication Supply Installation Testing And Commissioning Of Lt Main Distribution Panel Board And Ct Meter Cubicle Panel Board For Main Temple
Providing New Cubicle Mv Panel Board With 250A Sdfu, 100A Sdfu Along With 250 Amps Change Over Switch At Ce Office Building In Tangedco
Providing And Replacement Of Faulty Ht Metering Cubicle, L.T. Panel Board And Other Electrical Accessories In Muda Office Building, Muda