"नये भारत का नया Tender Portal"
Request a call back

Latest Tenders for pipe clip

Total 741 tenders found
#TBR: 35557999 Live

Education And Research Institutes

  • Rajasthan
  • Due On: 16 Oct, 2025 (5 Days Left)

"part-a (building Work) Based On Bsr Pwd - 2019, Dausa Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix Supplying And Filling In Plinth With Sandy Soil Free From Deleterious And Organic Material Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sandy Soil With All Lead And Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Beam:- Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Glazed Windows : Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required : Windows Side Hung /ventilators Top Or Centre Hung (openable) Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Gola Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : "copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M20 Grade Nominal Mix 1: 1.5: 3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size)." Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Sand Papering, Prime Coat, Making Smooth Surface With Cement Based Putty Etc Complete In All Respect: . New Work Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Door Frames:-providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry :size 100 X 75mm. P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills Counters, Floors Etc. Laid On 12mm (av.) Thick Base Of Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) Jointing With White Cement Mortar 1:2 (1white Cement : 2 Marble Dust) With Pigment To Match The Shade Of The Marble Slab Including Grinding, Rubbing And Polishing Complete.green / Blackabove 3601 Cm2 Slabs Providing And Fixing 1st Quality Standard White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 & Is :15622 Of Size 200mm X 300mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (excluding The Cost Of Cement Plaster On Walls And Pillar). "part-b (sanitary Work) Based On Bsr Pwd - 2014, Dausa Circle P & F Kitchen & Lab. Sink Of Approved Make With C.i. Brackets Duly Painted, 40 Mm C.p. Waste Coupling, C.p. Brass Chain With Rubber Plug, 40 Mm G.i. Waste Pipe Up-to Floor Level Complete Including Cutting And Making Good The Wall & Floor :wvc Lab Sink (is:2556 Mark) Size 530 X 430 X 180 Mm " P & F Chromium Plated Swan-neck Laboratory Cock Of Approved Quality / Make:one Way P & F Ball Cock (is :1703 Mark) With Rod & P.v.c. Ball Complete :brass Wt.400 Gm,15mm. P & F Inlet Connection (angle Valves) Superior Quality, Of Approved Make, For Wash Basin, Gyser Etc. C.p. Inlet Connection 15mm.brass (is : 8931 Marked) P & F 15 Mm. Dia Connection Pipe Of Approved Quality/make :(-do-) 450mm. P & F Full-way Valve (is:778 Mark) Or Wheel Valve Of Approved Make :gun-metal 15mm Nominal Bore. P & F Stop Cock (is :8931 Mark), Superior Quality & Of Approved Make:brass 400 Gm. 15mm Nominal Bore. P & F Pvc Storage Tank Isi Marked (is : 12701) Indicating The Bis License No), Of Approved Make With Cover, 25mm Dia 1m Long G.i. Over-flow Pipe & 25 Cm. Long Wash Out Pipe With Plug & Socket, Including Making Connection Etc., Complete Of Approved Design: 500 (-do-) P & F G.i. Pipes (external Work) With G.i. Fittings Excluding Union (is : 1239 Mark) Including Trenching & Refilling Earth Etc.15mm Dia Nominal Bore'b' Class P & F G.i. Pipes (external Work) With G.i. Fittings Excluding Union (is : 1239 Mark) Including Trenching & Refilling Earth Etc.25mm Dia Nominal Bore 'a' Class Construction Of Soakage Well In All Types Of Soil Of Approved Drawing, Top 90 Cm .portion In 450mm Thick Masonry With Cm 1:6, 80 Mm Thick Stone Slab Covering, Jointing Of Slab In Cm 1:3 ,ralthal, Kharanja 40mm Thick M-15 Grade C.c Flooring, Earth Work Etc . Complete Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr . Inner Dia 90 Cm & 10 To 12 Mtr Deep. "part-c (electric Work) Based On Bsr Pwd 2013, Jaipur Circle Wiring Of Light Point/fan Point/exhaust Fan Point/ Call Bell Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is: 694) Of Approved Make Group-2 Light Point Short Point (up To 3 Mtr.)" Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3 Pin 5 Amp. Light Plug Point With 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is: 694) Of Approved Make In Surface/reces Group - On Board S & F Follwing Sizes (dia.) Of Isi Marked Medium Duty Pvc Conduit Along With Accessories In Surface/ Recessed Using Clamps, Fastener As Required Including Cutting The Wall , Covering Conduit With Wire Mess And Making Good The Same As Required. Group-2 25 Mm Dia "supplying And Drawi;ng Fr Pvc Insulated & Unsheathed Flexible Copper Conductor Isi Marked (is:694) Of 1.1 Kv Grade And Approved Make In Existing Surface Ofr Necessed Conduit/ Casting Capping Including Making Connections Etc. As Required. Group-2 2 X 1.5 Sq. Mm" 2 X 2.5 Sq. Mm P & F 240/415 V Mcb Of Breaking Capacity Not Less Than 10 Ka (b/c/d Tripping Characteristic) Isi Marked Is 8828 (1996)/conforming To Iec 60898 In Existing Board/ Sheets Including Making Connections With Lugs, Testing Etc. As Required. Group-2 6 A To 32 A Rating P & F Recessed/ Surface Mounting Heavy Duty Horizontal Type Sheet Steel Distribution Board Phophatised/ Powder Painted Complete With 100 Amp Copper Copper Bus Bar, Shorting Link, Neutral, Earth Link And Din Bar, Conforming To Is 13032 & Is 8623 Including Making Internal Db Termination With Copper Lux, Testing Etc. As Reqd. . Group-2 Single Door(single Phase) 8 Way P & F Strip Fluorscent Tube Fitting Fabricated From (crca Sheet And Finished With Powder Coating/stove Enamelled Non Corrosive Uv Resist Ep Channel) Complete With Accessories(low Loss Copperchoke, Starter, Starter Seat)/electronic Choke With Terminal Block Duely Prewired With Copper Conducter Including Making Connection, Testing Etc. As Required(without Tube)1x36 Watts With Occb. Group-2 P & F Fluorscent Tube Rod In Existing Fixtures As Required, Minimum 3 Star Rating,36/40 Watts P & F Star Rated Double Ball Beari;ng Capacitor Start, Aluminium Body And Blade Ceiling Fan With Down Rod Upto 30 Cm With 3x1.5 Sqmm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc As Required.1200 Mm Sweep 3 Star Rated P & F Is:371 Marked 6 Amp Sufface Type Celling Rose Inculuding Making Commection Testing Etc. Grup-2 (e071400) P & F Isi Marked 6 Amp Bakelite Batten/ Angle Holder Including Making Connextion Testing Etc As Required P & F 18 Swg Ms Recessed Fan Box, Hexagonal/round Of Size 130mm Dia, Depth 75 Mm , 12mm Dia Rad Fan Hook With 100mm Length Extended On Eeach Side. Gourp-1 P & F 18 Swg Sheet Steel Boxes Duly Finisded With Two Coats Of Red Oxide And With Earthing Terminal Of Following Sizes (nominal Size) On Surfacae Or In Recessed As Required. 175 Mmx 100 Mmx60 Mm

30.35 Lacs
View Tender
#TBR: 35558799 Live

Education And Research Institutes

  • Rajasthan
  • Due On: 16 Oct, 2025 (5 Days Left)

Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size).floor Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Base Of Column Etc Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For Columns, Pillers, Posts,and Struts Etc "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix." "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix" Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levelsproviding M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc.good Soil Of Earthfilling Available Excavated Earth (excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix / Design Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038-1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : Copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Internal Finishing: Distempering With Oil Bound Washeble Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding New Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry:size 125 X 100mm P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Beam:- Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Glazed Windows : Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required : Windows Side Hung /ventilators Top Or Centre Hung (openable) Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Gola Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : "copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M20 Grade Nominal Mix 1: 1.5: 3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size)." Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Sand Papering, Prime Coat, Making Smooth Surface With Cement Based Putty Etc Complete In All Respect: . New Work Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Door Frames:-providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry :size 100 X 75mm. P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .

22.20 Lacs
View Tender
#TBR: 35558958 Live

Education And Research Institutes

  • Rajasthan
  • Due On: 16 Oct, 2025 (5 Days Left)

Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size).floor Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Base Of Column Etc Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For Columns, Pillers, Posts,and Struts Etc "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix." "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix" Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levelsproviding M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc.good Soil Of Earthfilling Available Excavated Earth (excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix / Design Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038-1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : Copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Internal Finishing: Distempering With Oil Bound Washeble Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding New Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry:size 125 X 100mm P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .

9.80 Lacs
View Tender
#TBR: 35559003 Live

Education And Research Institutes

  • Rajasthan
  • Due On: 16 Oct, 2025 (5 Days Left)

Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size).floor Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Base Of Column Etc Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For Columns, Pillers, Posts,and Struts Etc "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix." "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix" Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levelsproviding M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc.good Soil Of Earthfilling Available Excavated Earth (excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix / Design Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038-1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : Copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Internal Finishing: Distempering With Oil Bound Washeble Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding New Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry:size 125 X 100mm P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Beam:- Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Glazed Windows : Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required : Windows Side Hung /ventilators Top Or Centre Hung (openable) Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Gola Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : "copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M20 Grade Nominal Mix 1: 1.5: 3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size)." Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Sand Papering, Prime Coat, Making Smooth Surface With Cement Based Putty Etc Complete In All Respect: . New Work Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Door Frames:-providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry :size 100 X 75mm. P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " Pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Complete In Spcified Grade Excluding The Cost Of Centering And Shuttering All Work Upto Plinth Level 1:4:8(1 Cement:3 Coarse Sand :6 Graded Stone Aggregate 40 Mm Nominal Size). Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In Cement Mortat 1:6 (1-cement: 6- Sand) Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Bases Of Columns Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement M20 Grade Nominal Mix / Design Mix Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 100 In Superstructure Above Plinth Level Upto Floor V Level In. C.m.1:4 "supplying And Fixing Stone Lintels/bed Plates Of Approved Quarry Rough Dressed In Cement Mortar 1:4 Upto 15 Cm. Thick:" Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. "providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix " Stone Kharanja: Random Rubble Dry Stone Kharanja Under Floor "providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size)." Providing & Fixing Ist Quality Standard White, Gray, Ivory,fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 And Is: 15622 Of Size 300mm X 200mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of Tile Complete (excluding The Cost Of Cement Plaster On Walls And Piller) Providing And Fixing 1st Quality Mat Finished Ceremic Tile Size 300x300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (including The Cost Of Cement Mortar Bed 1:4). Door Frames : P & F T- Iron Frames For Doors , Windows And Ventilators Of Mild Steel , Tee Section Joints Mitred And Welded With 15x3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Blocks 15x10x10 Cm Of 1:3:6 (1 Cement:3 Fine Sand6 Graded Stone Aggregate 20 Mm Nominal Size:) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinged And Screws And Applying A Priming Coat Of Approved Steel Primer Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter Windows In Angle Iron Frame 35x35x5 Mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3 - Fine Sand) Internal Plaster :plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished : 12mm Thick External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished 20 Mm Thick Grading Roof For Water Proofing Treatment Cement Concrete 1: 2: 4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate 20 Mm Nominal Size) "providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038- 1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sashputty Of Approved Make Or Metal Beading With Screwscomplete Including Priming Coat Of Approval Steel Primer,excluding The Cost Of Metal Beading And Other Fitting Exceptnecessary Hinges Of Pivots Steel Handles Peg Stay Etc. Asrequired Partly Fixed And Partly Openable [ Fixed Area Not To Exceed33%]" "supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance" Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc.12mm Dia Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer "finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm )." Panting On Doors & Windows :- Painting With Syntheitic Enamel Paint Of Approved Brand And Manufacture In All Shade To Give An Even Shade New Steel Work (2 Or More Coat On New Work). Copping: Cement Concrete Flooring 1:2:4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate) Finishing With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc. Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete : 40mm Thick With 20mm Thick Nominal Size Aggregate. Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Light Shade Using Shade Cement.p Providing And Fixing Chlorinated Polyvinyl Chloride (cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/c Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (concealed Work Including Cutting Chases And Making Good The Walls Etc.,)20mm Nominal Outer Dia Pipes 25 Mm Nominal Outer Dia Pipes P & F Indian Type White Glazed Vitreous China 1st Quality W.c. Orissa Pan (is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 530*410mm "p & F Wvc Wash Basin (1st Quality, I.s. : 2556 Mark) Of Approved Make With C.i. Brackets Duly Painted, 1 No. 15 Mm C.p. Pillar Cock (is : 8934 Mark) & 32 Mm C.p. Brass Waste Coupling Of Approved Make,25 Mm G.i. Waste Pipe Complete Including Cutting & Making Good The Wall.: 450 X 300 Mm " P & F Bib Cock (is : 8931 Mark) Superior Quality Of Approved Make.c.p. Brass 400 Gm, 15 Mm Nominal Bore. P & F Inlet Connection (angle Valves) Superior Quality Of Approved Make C.p. Intel Connection 15 Mm Brass (is : 8931) P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii/ (4 Kg. /cm2.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia P & F Low Level Flushing Cistern Of 10 Litres Capacity (is : 2556mark). Of Approved Make With Complete Fittings C.i. Brackets Duly Painted, Brass Ball Cock With Ball, (is: 1703 Mark) Complete Including Cutting And Making Good The Wall:pvc With Pvc Bend And Superior Internal Fittings As Per Is :7231 P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant Plain Floor Trap 110 Mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant P-trap 110 Mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant Vent Cowel 110 Mm Dia S/f Rcc Main Hole Covers With Frame Of Approved Make (light Duty) Size 450x450 Mm P/f Grating Of Approved Quality Stainiese Steet Sheet Size 125 Mm Dia Construction Of Soakage Well In All Types Of Soil Of Approved Drawing , Top 90 Cm Portion In 450 Mm Thick With Cement Mortar 1:6 80 Mm Stone Slab Covering Jointing Of Slab In Cm 1 : 3, Ralthal, Kharanja, 40 Mm Thick M-15 Grade C.c. Flooring Earthwork Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.inner Dia 90 Cm & 10 To 12 M Deep Construction Of Chamber In All Types Of Soil With 300 Mm Thick Masnory In Cm. 1 : 6, 100 Mm Thick C.c. 1 : 5 : 10 In Foundation , 20 Mm Thick Inside Plaster In Cm 1 : 6, Finished With Floating Neat Cement 50 Mm Thick M-15 Grade C.c. Flooring Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.inside Size 450 X 450 Mm Depth Upto 0.5 M & 5 Kg Ci Cover With Frame. P & F Ball Cock (is : 1703 Mark) With Rod & P.v.c. Ball Complete.brass Wt. 300 Gm, 15 Mm P & F 15 Mm Dia Connection Pipe Of Approved Quality Make Pvc Pipes With Nuts 450 Mm. P & F Stop Cock (is:8931 Mark),superior Quality And Of Approved Mark: Brass 400 Gm. 15 Mm Nominal Bore P & F Pvc Storage Tank Isi Marked ( Is : 12701) Indicating The Bis License No. Of Approved Make With Cover , 25mm Dia 1 M Long G.i. Overflow Pipe & 25 Cm Long Wash Out Pipe With Plug & Socket Including Making Connection Etc. Complete Of Approved Design 500 Litres Capacity Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 25 Mm Dia Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X 1.5 Sq. Mm 2 X 2.5 Sq. Mm Providing & Fixing Of Heavy Duty Capacitor Start, Copper Woind Double Ball Bearing 900/1400 Rpm Single Phase Exhaust Fan As Per Pwd Specification For Electrical Works, Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. Oem Shall Be An Iso Certified Company. Appropriate Oem Test Certificate Shall Be Submitted By Contractor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 300 Mm Sweep (900/1400 Rpm) Earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size).floor Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Base Of Column Etc Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For Columns, Pillers, Posts,and Struts Etc "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levels Providing M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix." "providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement. M20 Grade Nominal Mix / Design Mix" Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix / Design Mix Add Extra For Providing Richer Mixes Respectively At All Floor Levelsproviding M-25 Grade Concrete By Using Cement As Per Codal Provision Instead Of M-20 Grade Design Mix. Supply & Stacking Good Soil Of Earth At Site Complete Including Loading Unloading & Transportation Etc.good Soil Of Earthfilling Available Excavated Earth (excluding Rock) In Trenches, Plinth Side Of Foundation Etc. In Layers Not Exceeding 20 Cm. In Depth, Consolidating Each Deposited Layer By Ramming And Watering Including Lead Up To 50 Meter And With All Lift. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix / Design Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038-1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required :partly Fixed And Partly Openable [ Fixed Area Not To Exceed 33%] Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : Copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M15 Grade Nominal Mix 1: 2: 4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size). Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Internal Finishing: Distempering With Oil Bound Washeble Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding New Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm ). Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry:size 125 X 100mm P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sum On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " "pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size)." Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In: Cement Mortar 1:6 ( 1-cement : 6-sand). Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation , Footings, Strap Beam, Raft , Bases Of Columns Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc. Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For : Columns, Pillars, Posts And Struts Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers (if Required ) Excluding The Cost Of Centering, Shuttering And Reinforcement For Walls (any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc.m20 Grade Nominal Mix Supplying And Filling In Plinth With Blown Sand Under Floors Including Watering Ramming Consolidating And Dressing Complete Including Cost Of Sand. Stone Kharanja : Random Rubble Dry Stone Kharanja Under Floor. Brick Work With Clay Flyash F.p.s. Brick Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) Beam:- Providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc.m20 Grade Nominal Mix Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. Thermo-mechanically Treated Bars (conforming Of Relevent Is Code) Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter In Angle Iron Frame 35x35x5mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint Extra For Double Leaf Shutters. Glazed Windows : Providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sash Putty Of Approved Make Or Metal Beading With Screws Complete Including Priming Coat Of Approval Steel Primer, Excluding The Cost Of Metal Beading And Other Fitting Except Necessary Hinges Of Pivots Steel Handles Peg Stay Etc. As Required : Windows Side Hung /ventilators Top Or Centre Hung (openable) Supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance. Guard Bars : Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc. Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm (average) Thick Base Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete With Base Of Cement Mortar 1 : 4 (1 Cement : 4 Coarse Sand) For Area Of Each Slab From 2001 To 5000 Sq.cm : Kota Stone Slabs 25 Mm Thick In Risers Of Steps, Skirting, Dado And Pillars Laid On 12 Mm (average) Thick Cement Mortar 1:3 (1 Cement 3 Coarse Sand) And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slabs, Including Rubbing And Polishing Complete For Area Of Each Slab Upto 2001 Sqcm Internal Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :12mm Thick. External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finish :20mm Thick. Plaster (ceiling): 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3-fine Sand) Grading Roof For Water Proofing Treatment With Water Proffing Compound Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) Gola Providing Gola 75x75 Mm In Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregate 10mm And Down Gauge) Including Finishing With Cement Mortar 1:3 (1 Cement : 3 Fine Sand) As Per Standard Design : "copping : Providing And Laying Cement Concrete Including Curing, Compaction Etc. Complete In Retaining Walls, Return Walls, Walls (any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Levelling Course Etc Up To Floor Five Level Excluding The Cost Of Centering And Shuttering. M20 Grade Nominal Mix 1: 1.5: 3 (1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size)." Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer. Painting Exterior Surface Of Wall With 100% Acrylic Exterior Paint Of Approved Brand And Manufacture To Give An Even Shade With Two Or More Coats Including Sand Papering, Prime Coat, Making Smooth Surface With Cement Based Putty Etc Complete In All Respect: . New Work Panting On Doors & Windows :- Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade : Two Or More Coats On New Work Door Frames:-providing And Fixing In Cm 1 : 4 Double Paitam (rebated) Stone Door Window And Ventilator Frames Of Approved Quarry :size 100 X 75mm. P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii(4 Kg. /cm.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia Pipe Clip 110mm Dia Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Mms (9537 P-111)pvc Condute.25mm. Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X1.5 Sqmm Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X2.5 Sqmm Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of Breaking Capacity Not Less Than 10 Ka (b/ C Tripping Characteristic As Per Type Of Load And Site Requirement) 4kv Impulse Withstand Voltage, As Per Pwd Specification For Electrical Works With Isi Marked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3 As Per Iec, Minimum Phase Termination Capacity Of 35sq.mm. , Conductorline Load Reversibility, Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board/sheets, Min. Operation 20,000 Upto 32 A Rating And 10,000 Upto 63 A, 5000 For 80 A Rating Including Making Connections, Testing Etc. As Required. . Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr .6a To 32a Rating. 50 A To 63a Rating Providing & Fixing Of Ip20 Smd Mid Power Led Batten Type Integrated Light Fixture Made From Polycarbonate /extruded Aluminium Powder Coated Housing With In Built Driver , Power Consumption Of 18w/20w ,system Lumen Efficacy = 120 Lm/watt Output, Internal Surge Protection Of 2.5 Kv With Short & Open Circuit Protection ,thd < 10% ,p.f.=0.95, Cri >80 , Life Time Of Minimum 50000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. 1170mm(+/-10%) Led Batten With Min. Lumen Output 2200 Lm Providing & Fixing Of Energy Efficient /energy Saving Ip 20 Led Direct Retrofit Bulb In Existing Holder Or Fixture As Required With System Lumen Efficacy =100 Lm/watt Output ,pf 0.95 , Cri >70, Minimum Life Time Of Minimum 25000 Burning Hours With , 70% Of Intial Lumen Maintaned Till Life Ends , Cct 3000°k / 4000°k / 5700°k /6000°k/6500°k (as Per Ansi Bin) , Maximum Power Consumption Should Not More Than The Specified Rating And Fixture Shall Be Of Bis Standard And Trade Mark Certificate ( T.c.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen Printing On Housing. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Led Fixtures. (lm79/lm80) Certificate / Report From Oem Shall Be Submitted. All As Per Pre Approved By Engineer In Charge . For Additional Technical Parameters Of Product/ Work, Refer Annexure "a" Attacheded With This Bsr.6/7 Watt Providing & Laying P.v.c. / Xlpe Insulated & P.v.c. Sheathed Un-arrmoured Aluminium Cable Confirming To Is:1554 P-i / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/cable Trench / Cable Tray (with Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have It's Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr 6.0 Sq. Mm 4 Core Providing & Fixing Of Bee Star Rated Copper Wounded Double Ball Bearing Capacitor Start, Aluminium Body & Metallic Blade Ceiling Fan Conforming To All The Performance Requirements Laid Down In Is 374:2019 Including All Amendments, As Applicable ; & Carry Bis Licensing (i.e. Isi Marking) With Down Rod Up To 80 Cm With Secondary Support Safety Cable ( Steel Rope) , Cotter Pin With 3 X 1.5 Sq.mm Pvc Insulated Flexible Copper Conductor Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Isi Marked (is:1258) Batten/angle Lamp Holder With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal & Captive Screwsincluding Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . P & F 1.2mm Thick M.s. Recessed Fan Box, Hexagonal/ Round Of Size 130 Mm Dia, Depth 75mm, 12 Mm Dia Rod Fan Hook With 100 Mm Length Extended On Each Side . All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr Providing & Fixing Of 240/415 V Isolator As Per Pwd Specification For Electrical Works With Isi Marked Is:13947-iii/conforming To Iec 60947-3, Suitable For Ac22a Utilization Catagory, 4kv Impulse Withstand Voltage, True Contact Indication, Red Colour Dolly / Lever Shall Have Single Mould Covering Over All Poles For Operation , Two Position Din Rail Mounting, Minimum Phase Termination Capacity Of 35sq.mm. , Label Holding Facility , Ip 20 Contact Protection And Fitted With Existing Distribution Board / Sheet Including Making Connections, Testing Etc. As Required. Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Test Reports Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 30/40 Amp Rating . Providing & Fixing Of Modular Type 120 W Step Fan Regulator Duly Isi Marked (is 11037:1984 ) With Cm/l No. Printed Made Out Of Unbreakable And Fire Retardant Vergin Poly Carbonate With Brass Terminals And Captive Screws & Silver Alloy Contact Tip With Ip-20 Rating , Including All As Per Pre Approved By Engineer In Charge,making Connections, Testing Etc. As Required. For Additional Technical Parameters Of Product / Work Refer Annexure 'a' Attached With This Bsr5 Step Fan Regulator 2 Module 360 Dgree Rotating P & F Isi Marked (is:3854) 6 Amp. Flush Type Non Modular Switch With Cm/l No. Printed And Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material Including Cutting Hole In Tile And Making Connection Testing Etc. As Required. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Providing & Fixing Of Of 3/5 Pin 6 Amp. Flush Type Non Modular Socket Made Out From Industrial Grade Polycarbonate Or Fire Resistant Abs Material, Brass Terminal With Porcelain Based Back Cover & Captive Screws Including Cutting Hole In Tile And Making Connection Testing Etc. As Required.all As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . "earth Work In Excavation By Mechanical Means (hydraulic Excavator )/ Manual Means In Foundation Trenches Or Drains (not Exceeding 1.5 M In Width Or 10 Sqm On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter. All Kinds Of Soils " Pcc In Foundation : Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Complete In Spcified Grade Excluding The Cost Of Centering And Shuttering All Work Upto Plinth Level 1:4:8(1 Cement:3 Coarse Sand :6 Graded Stone Aggregate 40 Mm Nominal Size). Random Rubble Stone Masonry For With Hard Stone In Foundation And Plinth In Cement Sand Mortar Above 30 Cm Thick Wall In Cement Mortat 1:6 (1-cement: 6- Sand) Centering And Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways And Removal Of Formwork For Foundation, Footings, Strap Beam, Raft, Bases Of Columns Etc. Providing And Laying In Position Specified Grade Of Cement Concrete For All Rcc Structural Elements Upto Plinth Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement M20 Grade Nominal Mix / Design Mix Brick Work With Clay Flyash F.p.s. Brick (is 13757- 1993 ) Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor Five Level In : Cement Mortar 1 : 6 (1 Cement : 6 Coarse Sand) Half Brick Work With Mechanised Autoclaved Flyash Lime Bricks Conforming To Is: 12894 :2002 Of Class Designation 100 In Superstructure Above Plinth Level Upto Floor V Level In. C.m.1:4 "supplying And Fixing Stone Lintels/bed Plates Of Approved Quarry Rough Dressed In Cement Mortar 1:4 Upto 15 Cm. Thick:" Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Props And Removal Of Formwork For Upto Floor Five Level For :suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands, Coping Bed Plates, Anchor Blocks, Sills, Chhajjas, Lintel, Beam, Plinth Beam Etc Providing And Fabricating Reinforcement For R.c.c. Work Including Straightening, Cutting, Bending, Placing In Position And Binding (including Cost Of Binding Wire) All Complete Up To Floor Five Level. "providing And Laying In Position Specified Grade Of Cement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 (1 Cement: 3 Coarse Sand) And Making Good The Joints And Cost Of Plastizers( If Required) Excluding The Cost Of Centering, Shuttering And Reinforcement For Beams, Suspended Floors, Roofs, Griders Having Slopes Up To 15º, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Windows Sills, Staircases And Spiral Staircases Etc. M20 Grade Nominal Mix / Design Mix " Stone Kharanja: Random Rubble Dry Stone Kharanja Under Floor "providing And Laying In Position Cement Concrete Including Curing, Compaction Etc. Complete In Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level. M10 Grade Nominal Mix 1: 3: 6 (1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size)." Providing & Fixing Ist Quality Standard White, Gray, Ivory,fume Red Brown, Light Green, Light Blue And Other Light Shades Glazed Tiles Confirming To Is : 13753 And Is: 15622 Of Size 300mm X 200mm In Walls, Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of Tile Complete (excluding The Cost Of Cement Plaster On Walls And Piller) Providing And Fixing 1st Quality Mat Finished Ceremic Tile Size 300x300mm Confirming To Is : 13755 And Is : 15622 Colour Such As White, Grey, Ivory, Fume Red Brown, Light Green, Light Blue And Other Light Shades In Floors, Steps, Pillars Etc. Laid On A Bed Of Neat Cement Slurry Finished With Flush Pointing In The White Cement Mixed With Pigment To Match The Shade Of The Tile Complete (including The Cost Of Cement Mortar Bed 1:4). Door Frames : P & F T- Iron Frames For Doors , Windows And Ventilators Of Mild Steel , Tee Section Joints Mitred And Welded With 15x3 Mm Lugs 10 Cm Long Embedded In Cement Concrete Blocks 15x10x10 Cm Of 1:3:6 (1 Cement:3 Fine Sand6 Graded Stone Aggregate 20 Mm Nominal Size:) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinged And Screws And Applying A Priming Coat Of Approved Steel Primer Providing And Fixing M.s. Sheet 1mm Thick Single Leaf Door Shutter Windows In Angle Iron Frame 35x35x5 Mm Suitabilly Diagonally Braced With 25x3mm Flat Iron Above And Below Lock Rail Of Size 50x5mm Beading Extra Including All Fittings, As Per Direction Of Engg. Incharge But Excluding Cost Of Chowkhats: Including Two Coats Of Anit-corrosive Red Oxide Primer Paint 6 Mm Thick Cement Plaster To Ceiling Of Mix 1:3 (1cement : 3 - Fine Sand) Internal Plaster :plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished : 12mm Thick External Plaster : Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished 20 Mm Thick Grading Roof For Water Proofing Treatment Cement Concrete 1: 2: 4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate 20 Mm Nominal Size) "providing And Fixing Steel Glazed Doors Windows And Ventilator Shutters Of Standard Rolled Steel Section (is 1038- 1983) Joints Mitred And Welded With Steel Lugs 13x3mm, 10cm. Long Embedded In Cement Concrete Block 15x10x10cm. Of 1:3:6 (1cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20mm Nominal Size) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws With Fixing Clips Or With Bolts And Nuts As Required Including Providing And Fixing Of Plain Glass Panes 4mm Thick With Cooper Glazing Clips And Special Metal Sashputty Of Approved Make Or Metal Beading With Screwscomplete Including Priming Coat Of Approval Steel Primer,excluding The Cost Of Metal Beading And Other Fitting Exceptnecessary Hinges Of Pivots Steel Handles Peg Stay Etc. Asrequired Partly Fixed And Partly Openable [ Fixed Area Not To Exceed33%]" "supplying And Fixing Fixed Wire Gauge Of 14 Mesh X 24 Gauge To The Metal Frame Of Rolled Section By Metal Beading 20x3mm With Suitable Screw At Not Exceeding 150mm Distance" Providing And Fixing Square Bars Or Other Flat Welded To Window, Ventilatiors Etc.12mm Dia Providing And Applying White Cement Based Putty Over Plastered Surface To Prepare The Surface Even And Smooth Complete Distempering With Oil Bound Washable Distemper Of Approved Brand And Manufacture To Give An Even Shade Including All Scaffolding:new Work (two Or More Coats) Over And Including Scrapping And Priming Coat With Cement Primer "finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Including All Scaffolding. New Work (two Or More Coat Applied @ 1.67 Ltr/10 Sqm Over And Including Base Coat Of Water Proofing Cement Paint Applied @ 2.20 Kg/ 10 Sqm )." Panting On Doors & Windows :- Painting With Syntheitic Enamel Paint Of Approved Brand And Manufacture In All Shade To Give An Even Shade New Steel Work (2 Or More Coat On New Work). Copping: Cement Concrete Flooring 1:2:4 (1 Cement: 2 Course Sand: 4 Greded Stone Aggregate) Finishing With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc. Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete : 40mm Thick With 20mm Thick Nominal Size Aggregate. Chequerred Precast Cement Concrete Tiles 22 Mm Thick In Footpath & Courtyard Jointed With Neat Cement Slurry Mixed With Pigment To Match The Shade Of Tiles Including Rubbing And Cleaning Etc. Complete On 20 Mm Thick Bed Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Light Shade Using Shade Cement.p Providing And Fixing Chlorinated Polyvinyl Chloride (cpvc) Pipes, Having Thermal Stability For Hot & Cold Water Supply Including All Cpvc Plain & Brass Threaded Fittings I/c Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer In Charge. (concealed Work Including Cutting Chases And Making Good The Walls Etc.,)20mm Nominal Outer Dia Pipes 25 Mm Nominal Outer Dia Pipes P & F Indian Type White Glazed Vitreous China 1st Quality W.c. Orissa Pan (is :2556 Mark) With 100 Mm Vitreous China P Or S Trap Including Cutting And Making Good The Wall And Floor: Size 530*410mm "p & F Wvc Wash Basin (1st Quality, I.s. : 2556 Mark) Of Approved Make With C.i. Brackets Duly Painted, 1 No. 15 Mm C.p. Pillar Cock (is : 8934 Mark) & 32 Mm C.p. Brass Waste Coupling Of Approved Make,25 Mm G.i. Waste Pipe Complete Including Cutting & Making Good The Wall.: 450 X 300 Mm " P & F Bib Cock (is : 8931 Mark) Superior Quality Of Approved Make.c.p. Brass 400 Gm, 15 Mm Nominal Bore. P & F Inlet Connection (angle Valves) Superior Quality Of Approved Make C.p. Intel Connection 15 Mm Brass (is : 8931) P&f Rigid Pvc Pipe (is:4985 Mark) Class Ii/ (4 Kg. /cm2.) Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant. 110 Mm Dia P & F Low Level Flushing Cistern Of 10 Litres Capacity (is : 2556mark). Of Approved Make With Complete Fittings C.i. Brackets Duly Painted, Brass Ball Cock With Ball, (is: 1703 Mark) Complete Including Cutting And Making Good The Wall:pvc With Pvc Bend And Superior Internal Fittings As Per Is :7231 P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant: Bend 87.5 110mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant Plain Floor Trap 110 Mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant P-trap 110 Mm Dia P&f Rigid Pvc Pipe Fittings (is: 4985 Mark) Of Approved Quality /make Including Joining The Pipe With Solvent Cement Rubber Ring And Lubricant Vent Cowel 110 Mm Dia S/f Rcc Main Hole Covers With Frame Of Approved Make (light Duty) Size 450x450 Mm P/f Grating Of Approved Quality Stainiese Steet Sheet Size 125 Mm Dia Construction Of Soakage Well In All Types Of Soil Of Approved Drawing , Top 90 Cm Portion In 450 Mm Thick With Cement Mortar 1:6 80 Mm Stone Slab Covering Jointing Of Slab In Cm 1 : 3, Ralthal, Kharanja, 40 Mm Thick M-15 Grade C.c. Flooring Earthwork Etc. Complete As Per Approved Drawing Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.inner Dia 90 Cm & 10 To 12 M Deep Construction Of Chamber In All Types Of Soil With 300 Mm Thick Masnory In Cm. 1 : 6, 100 Mm Thick C.c. 1 : 5 : 10 In Foundation , 20 Mm Thick Inside Plaster In Cm 1 : 6, Finished With Floating Neat Cement 50 Mm Thick M-15 Grade C.c. Flooring Earthwork Etc. Complete As Per Design Including Disposal Of Surplus Earth Within A Lead Of 50 Mtr.inside Size 450 X 450 Mm Depth Upto 0.5 M & 5 Kg Ci Cover With Frame. P & F Ball Cock (is : 1703 Mark) With Rod & P.v.c. Ball Complete.brass Wt. 300 Gm, 15 Mm P & F 15 Mm Dia Connection Pipe Of Approved Quality Make Pvc Pipes With Nuts 450 Mm. P & F Stop Cock (is:8931 Mark),superior Quality And Of Approved Mark: Brass 400 Gm. 15 Mm Nominal Bore P & F Pvc Storage Tank Isi Marked ( Is : 12701) Indicating The Bis License No. Of Approved Make With Cover , 25mm Dia 1 M Long G.i. Overflow Pipe & 25 Cm Long Wash Out Pipe With Plug & Socket Including Making Connection Etc. Complete Of Approved Design 500 Litres Capacity Wiring Of Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg Hot Dipped Galvanized Modular Box With Earth Terminal, 6 A Modular Switch, Modular Face Plate With Grid Plate, 3 Pin Ceiling Rose / Lamp Holder/ 3 Pin Connector , Screws Etc, Making Connections,all As Per Pre Approved By Engineer In Charge, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07 . For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . Short Point (up To 3 Mtr.) Medium Point (up To 6 Mtr) Long Point (up To 10 Mtr) Wiring Of 3/5 Pin 6 Amp. Light Plug Point As Per Pwd Specification For Electrical Works With Isi Marked 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Conductor 1.1 Kv Grade (is:694) And 1.5 Sq. Mm Nominal Size Fr Pvc Insulated Unsheathed Flexible Copper Earth Conductor 1.1 Kv Grade (is:694) In Recessed Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit & It's All Accessories( J.b. , Bends Etc.) , Round Tiles,18 Swg G.i. Box With Earth Terminal Of Required Size, 6 A Switch, 3/5 Pin 6 A Socket, 3.0 Mm Thick Isi Marked Phenolic Laminated Sheet (is : 2036 - 1995), Al. Alloy/ Cadmium Plated Iron Screws 20 Mm Cup Washers Etc. All As Per Pre Approved By Engineer In Charge, Making Connections, Testing Etc. Complete As Required. For Specification Of Copper Conductor, Phenolic Laminated Sheet's & Electrical/ Wiring Accessories Refer Chapter E - 04, E - 05 & E - 07. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . On Board S&f Following Sizes (dia.) Of Isi Marked Mms ( Is:9537 P - Iii ) Vergin Material Pvc Conduit As Per Pwd Specification For Electrical Works Along With Its Accessories (is: 3419 ) As Required In Recess Including Cutting The Wall, Covering Conduit And Making Good The Same As Required. All Relative And Latest Acceptance Tests Reports By Any Nabl Accredited Lab For The Conduit Shall Be Submitted Before Execution & All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 25 Mm Dia Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copper Conductor As Per Pwd Specification For Electrical Works With Isi Marked (is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Should Be Made From 99.99% Purity Copper, Class 5 Stranding In Acc. To Iec 60228 For Lower Watt Loss , Oxygen Free ( <10 Ppm) For Less Chances Of Oxidization And Higher Silver Content For Gives Better Conductivity , Insulation Pvc Type A ,flame Retardant As Per Is 10810-53, Better Amperage Rating As Per Vde 0298 Part 4, , In Existing Surface Or Recessed Pvc/ Ms Conduit/casing Capping Including All As Per Pre Approved By Engineer In Charge,making Connections, Etc. As Required. Oem Must Have Its Own In House Nabl Lab Setup For All Testing Facilities For Wires. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 2 X 1.5 Sq. Mm 2 X 2.5 Sq. Mm Providing & Fixing Of Heavy Duty Capacitor Start, Copper Woind Double Ball Bearing 900/1400 Rpm Single Phase Exhaust Fan As Per Pwd Specification For Electrical Works, Conforming To Is:2312 Isi Marked In Existing Opening Including Making Connections Testing Etc. As Required. Oem Shall Be An Iso Certified Company. Appropriate Oem Test Certificate Shall Be Submitted By Contractor. All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure "a" Attached With This Bsr . 300 Mm Sweep (900/1400 Rpm)

25.85 Lacs
View Tender
#TBR: 35513199 Live

Security Services

  • Uttar Pradesh
  • Due On: 11 Oct, 2025 (0 Days Left)

Gem Bids For Misc, Bid Number Gem2025b6694799 Dated 01-10-2025 Bid Document1 85 0 0 Non - Modular Piano Type Domestic Electrical Switches Asper Is 3854 Q3, Piano Type Non Modular Domestic Fanregulator As Per Is 11037 Q3, Piano Type Modulardomestic Fan Regulator As Per Is 11037 Q3, Piano Typenon Modular Electrical Switch Socket Combination As Per Is3854 And Is 1293 Q3, Piano Type Non Modular Domesticelectrical Sockets - Is 1293 Q3, Ceiling Rose - Is 371 Q3, Electrical Plugs V2 Isi Marked To Is 1293 Q2, Piano Typemodular Domestic Electrical Sockets - Is 1293 Q3, Modularelectrical Enclosure Switch Board Boxes For Modular Typeaccessories Q3, Modular Socket 6 Amp 5 Pin, Modularswitch 16 Amp, Modular Switch 6 Amp, Angle Holder, Batten Holder, Socket Flush Type 5 To 6 Amp With 3 To 5 Pin, Heat Shrinkable Straight Through 95 Sqmm X 3 Core, 11 Kvend Terminatrion., Heat Shrinkable Straight Through 120Sqmm X 3 Core, 11 Kv End Terminatrion., Heat Shrinkablecable Joint 10 Sqmm 2 Core, Heat Shrinkable Cable Joint 16Sqmm 2 Core, Heat Shrinkable Cable Joint 10 Sqmm, Heatshrinkable Cable Joint 16 Sqmm, Heat Shrinkable Cable Joint25 Sqmm, Heat Shrinkable Cable Joint 35 Sqmm, Heatshrinkable Cable Joint 50 Sqmm, Heat Shrinkable Cable Joint70 Sqmm, Heat Shrinkable Cable Joint 95 Sqmm, Heatshrinkable Cable Joint 120 Sqmm, Heat Shrinkable Cablejoint 150 Sqmm, Heat Shrinkable Cable Joint 185 Sqmm, Heat Shrinkable Cable Joint 240 Sqmm, Condensor 2.5 Mfd, Condensor 4 Mfd, Ding Dong Bell, Buzzer Electric, Insulationtape 15 Mm X 25 Mtr Long, Insulationtape 20Mm X 25 Mtr Long, Insulation Tape 25 Mm X 25 Mtr Long, Ht Tape, Pvc Casing Caping 20Mm, Pvc Conduite Pipe25mm, Pvc Conduite Pipe 32Mm, Pvc Saddle Clip For Cable8 Mm, Pvc Saddle Clip For Cable 25 Mm, Heating Element2000w Cup Or Thread Type, Heating Element 2000W, Heating Element 1500W, 3 Kw Heating Element, Gasket Fortransformer Sheet, Foam For Gap Filling In Electrical Paneldb And 1 Ltr Pkt, Crc Liquid For Preventing Corrosingn And500 Ml Pkt, Geyser Element 2 Kv, Ac Gang Box Switchsocket And Top With Mcb 25 Amp, Change Over Switch 100Amp, Change Over Switch 200 Amp, Change Over Switch400 Amp, Contactor Mnx-50, Contactor Mnx-70, Contactor Mnx-95, Modular Cover Plate 3 Module Withframe, Modular Cover Plate 4 Module With Frame, Modularcover Plate 6 Module With Frame, Cotton Waste, Pig Lead, Lead Acid Battery 12 V 90 100 Ah, Lead Acid Battery 12 V90 150 Ah, Lead Acid Battery 12 V 90 180 Ah, Thermostate For Geyser, Astronomical Timer For Streetlight Control, Soft Starter Vfd Suitable For 50 Hp Motor, Kitfan Motor For Desert Cooler, Water Pump 40 Watt For Desercooler, Fully Automatic Oil Immersed Auto Transformermotor Starter, Fully Automatic Oil Immersed Autotransformer Motor Starter For 75Hp Motor, Compressor 220-280 V, Weight 18 Kg For Split Ac 1.5 Or 2 Tr, Compressor 50Plus 4 Or 50 Plus 6 Mfd Rotary Type Suitable For Split Ac 1.5Or 2 Tr, Electronic Pcb Plate For Split And Window Acsuitable For 1.5 Or 2 Tr, Solar Street Light Ng Series 40 W    //Bid Details2 / 85

Ref. Document
View Tender
#TBR: 35506096 Live

Security Services

  • Delhi
  • Due On: 10 Oct, 2025 (0 Days Left)

Gem Bids For Procurement, Bid Number Gem2025b6631584 Dated 30-09-2025 Bid Document1 48 1 1 332 D5695 Sealant Hylomar 607 3Dx Super Eng Xxxiiig, 332 Y6292 Pivot Pin Kingpost 3Dx Super Ch Vi D, 32Ap Ba100 Hose 3 By 8 Bsp 1000 3Dx Super Ch Xiii A, 334 Y6169 Hose 10 Bsp Hp 850 Hyd Pump To Steer Va3dx Super Ch Iv A, 4102 2800 Sealant Yellow Sikaflex221 30Ml 3Dx Super Ch Iii H, 126 01153 Lever Parkingbrake 1, 336 Y2341 Chart Lubricant 3Dx Super Ch Iva, 730 03601 Fire Extinguisher 3Dx Super Ch Vii E, 336 Y2342 Decal Warning 3Dx Super Ch Iv A, 333Y9063 Stopper Plate 3Dx Super Ch Iv B, 333 Y0334liner Roof Assembly 3Dx Super Ch Iv F, 4101 1100Loctite 243 3Dx Super Ch Iv F T, 335 Y9798 Pipe Coverfront 3Dx Super Ch Iv W, 335 Y9799 Pipe Cover Sideleft Hand 3Dx Super Ch Iv W, 335 Y9803 Cover Pipefront 3Dx Super Ch Iv W, 335 Y9804 Cover Pipe Sideright Hand 3Dx Super Ch Iv W, 332 G6710 Clampingring 3Dx Super Ch Iv W, 334 Y7743 Console Front3dx Super Ch Iv Aa, 335 Y9811 Rear Valance 3Dxsuper Ch Iv Ai, 4101 0300 Fluid Locking 3Dx Super Chvi H, 225 35203 Mount Resilient 3Dx Super Ch Xii A, 333 Y3532 Steering Column Assembly Fixed 3Dx Superch Xii A Ch Xxx1 Aa, 336 Y2361 Decal Dipper 3Dx Superarmy 3Dx Super Ch Vii A, 336 Y2563 Jcb Decalartwork Armay 3Dx Super Ch Vii A, 335 Y6827 Hose Stpump 3Dx Super Ch Xiii H, 335 Y7881 Bracketmounting Fire Extinguisher 3Dx Super Ch Vii D, 335B2589 Hose 6 Bsp Hp 2020Mm 3Dx Super Ch Xvii B, 335E6978 Bush Cylinder 3Dx Super Ch Xvi N, 335 Y0614bracket Side Panel Mounting 3Dx Super Ch Xxviii B, 334 Y0568 Plate Anti Re Circ 3Dx Super Ch Xxviii C, 334 Y2232 Bracket Hose Guide 3Dx Super Ch Xxviii E, 320 08587 Bracket Idler Non Ac 3Dx Super Ch Xxix B, 128 17521 Pivots Clam Jaw 3Dx Super Ch Xxxi A, 81120008 Pin Pivot 600Mm 23 Inch Wide Jaw 3Dx Super Chxxxi F, 1089 0005 Collar 3Dx Super Ch Xxxi F, 400P9452 Pin 44 Point 45 44 Point 35X273 3Dx Super Ch Xxxif, 400 R5051 Bush 55 45 3Dx Super Ch Xxxi F, 332Y2824 Hose 3Dx Super Ch Xxxi P, 334 Y0469 Manifoldga Valve 3Dx Super Ch Xxxi Aa, 334 Y4823 Mountingfiller Tube, 335 Y4101 Housing Grille Assembly, 64605325 Cleaner Active Wiper, 646 05322 Frame Sealant, 333 Y1009 Plate Stowage Lid Leftside, 333 Y1038 Boxstorage Right Hand, 333 Y1037 Plate Stowage Lid Rightside, 332 Y5799 Lever, 334 Y0789 Plate Cover Excavator, 13099555 Spanner D E 36 X 41Mm 36 X 41 Mm, 130 99507Tube Extension Bar 3 By 4 Inch X 210Mm, 130 14008 Singleend Spanner 60 Mm, 40 304448 D E Spanner 1 Inch 1 1 By8 Inch, 4003 2006 Grease High Pressure 12 Point 5Kg Qty Ar, 4003 2005 Grease High Pressure 50Kg Qty A R, 40002501 Fluid Jcb Ep Transmission 10W 5 Litre Qty A R, 40002505 Fluid Jcb Ep Transmission 10W 20 Litre Qty A R, 40002202 Oil Jcb Hp Gear Oil 5 Litre Qty A R, 4000 2205 Oil Jcbhp Gear Oil 20 Litre Qty A R, 40 303795 Pedal Ga Auxvalve, 40 301773 Hose Unqin, 4102 3400 Sealantadhesive, 336 C7414 Jaw Front, 336 D0542 Hydraulics Jawbucket, 336 D1093 Bucket Square Hole, 335 Y0009 Valveregular Flow, 130 07243 Pin Locking, 445 19808Washer Thrust 3 Point 5Mm Thick Phosphated, 32008593 Washer Idler Retainer, 320 08631 Bolt Flangehead M10 X50, 821 10416 Clip Pipe Approx 27Mm Dia, 831 10298 Bush Selector Fork, 913 00014 Clevis Pin, 40 303524 Plate Baffle Oil, 40 302815 Tyre Front 12Point 5X80, 40 301924 Tyre Rear 16 Point 9X28    //Bid Details2 / 48 Point 5X80, 40 301924 Tyre Rear 16 Point 9X28

Ref. Document
View Tender
#TBR: 35510907 Live

Railway Transport

  • Uttar Pradesh
  • Due On: 14 Oct, 2025 (3 Days Left)

Supply Of Pipe Clip 25 Mm As Per Irs Drg. No. C/lf-533, Alt.-nil.

Ref. Document
View Tender
#TBR: 35514496 Live

Power Plant

  • Himachal Pradesh
  • Due On: 22 Oct, 2025 (11 Days Left)

Gem Bids For Purchase, Suction Pipe Pvc 200 Mm, Hose Pipe Dia 4 Inch, Clipfor Flexible Hose Pipe 200 Mm Id, Clip For Flexiblehose Pipe 100 Mm Id, Pipe Ayssembly 3 Way 250Mm200mm 200Mm, Pipe Assembly 3 Way 200Mm 100Mm100mm, Pipe, Pipe Assembly 2 Way 200Mm On One Sideand 100 Mm On Top Side

7.84 Lacs
View Tender
#TBR: 35498852 Closed

Security Services

  • Rajasthan
  • Due On: 09 Oct, 2025 (0 Days Left)

Gem Bids For Cabin, Cabin Lifting Seal, Snap Ring, Valve Seal Gasket, Hose 3Mtr, Spring With Washer Clip, High Pressure Fuel Pipe, High Pressure Hose Flexible Thermoplastic

Ref. Document
View Tender
#TBR: 35448142 Closed

Security Services

  • Uttaranchal
  • Due On: 03 Oct, 2025 (0 Days Left)

Gem Bids For Laundry Basket, Bed Side Runner 5X2, Carpet 7.5X5.5, Carpet 6X4, Door Mat Indoor, Tentive Card With Pkt, Tentive Card Envelope, Best Wishes Strip, Door Mat 7X2, Adopter For Led Bd 400W, Nyion Rope, Both Side Tape 1Inch, Clip For Flexible Wire, Male Female Set, Combinedswitch, Led Strip 5Mtr, Adopter For Led, Insulation Tape, Godrej Air Combo, Plastic 25 Ltr, Plastic Mug, Chopping Bd, Electric Wire Less Call Bell, Liquid Soap Dispenser, Toothbrush Holder, Curtains Rod, Pilot Pen Friction, Deo Drainperfume, Stabilizer 4 Kva, Roller Blind Cdr Office, Durosoftpremium 4X2, Green Grass 6X2, Green Grass 4X2, Greengrass 5X2, Durosoft Premium 8X2, Green Grass 8X2, Bulb0 Watt, Flat Wire, Pendent Holder, Durosoft Premium 3X2, Wall Fan Small, Wall Fan Large, Dustbin Steel, Dustbin Steelpedalbin, Acrylic Letter Cdr Bd, Golden Strip Frame, 11X5laminated Envelope, Do Pad Cdr, Invitation Card Cdr, Envelope For Card, Printed Strip For Card, Mirror For Cdroffice, Computer Table, Birpur Home Flag 6X4, Do Pad Cdrlarge, 40 76 Flexible Wire, W W Led Pipe Philips, Clip Forpipe, Mosquito Racket  /Bid Number: Gem/2025/B/6707823* /Dated: 22-09-2025  & & / Bid Document1 / 42

Ref. Document
View Tender
Download Document