"नये भारत का नया Tender Portal"
Request a call back

Latest Tenders for airconditioning unit

Total 11 tenders found
#TBR: 34565118 Closed

Construction

  • Maharashtra
  • Due On: 07 Jun, 2025 (0 Days Left)

Providing Renovation To Electrical Installation Switchgears Computer And Telephone Wiring Fans And Fittings And Airconditioning Unit Etc For Finance Dept On 3rd Floor At New Administrative Building Mumbai

15.29 Lacs
View Tender
#TBR: 34404950 Closed

Air Transport

  • Uttar Pradesh
  • Due On: 30 Apr, 2025 (0 Days Left)

Gem Bids For "comprehensive Maintenance Contract Of All Vrv/ Vrf System Including All Idu & Odu Of All Capacity, Ahus & Tfas, Referigerant Copper Pipe, Drain Pipe, Inline Fan, Duct/pvc Pipe With Lt Panel For Odu & Idu Including All Installation As Mentioned In Appendix I Installed In Interim Terminal Building, Kushinagar International Airport I/c Carrying Out Monthly Visit For Servicing And Maintenance Of All Components As Per Oem Standards By Providing Trained Service Engineer With All Tools And Plant And Spares I/c Attending All Breakdown Repairs As & When Required Etc. Complete As Per Instructions Of Engineer In-charge As Required. Note - Total Capacity Of Vrv/vrf Odu Is 400 Hp Of Dakin Make. First Year " "comprehensive Maintenance Contract Of All Vrv/ Vrf System Including All Idu & Odu Of All Capacity, Ahus & Tfas, Referigerant Copper Pipe, Drain Pipe, Inline Fan, Duct/pvc Pipe With Lt Panel For Odu & Idu Including All Installation As Mentioned In Appendix I Installed In Interim Terminal Building, Kushinagar International Airport I/c Carrying Out Monthly Visit For Servicing And Maintenance Of All Components As Per Oem Standards By Providing Trained Service Engineer With All Tools And Plant And Spares I/c Attending All Breakdown Repairs As & When Required Etc. Complete As Per Instructions Of Engineer In-charge As Required. Note - Total Capacity Of Vrv/vrf Odu Is 400 Hp Of Dakin Make. Second Year " "annual Comprehensive Maintenance Of 1.0 Tr, 1.5 Tr And 2.0 Tr Split Type Air Conditioners Of M/s Voltas/carrier/hitachi/lg/haier Etc. Make Installed At Different Locations Of Kushinagar International Airport As Mentioned In Appendix I. Works Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Ac Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Handset Say Remote, Thermostats, Capacitors, Selector Switches, Expansion Valve Etc. And Maintaing Records/ Documentation As Per Engineer In Charge And As Per Special Condition Of The Contract. Note - 1 Job Equal To Acmc Of 1 No Split Ac (1.0 Tr/1.5 /2.0 Tr) For 1 Year. First Year" "annual Comprehensive Maintenance Of 1.0 Tr, 1.5 Tr And 2.0 Tr Split Type Air Conditioners Of M/s Voltas/carrier/hitachi/lg/haier Etc. Make Installed At Different Locations Of Kushinagar International Airport As Mentioned In Appendix I. Works Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Ac Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Handset Say Remote, Thermostats, Capacitors, Selector Switches, Expansion Valve Etc. And Maintaing Records/ Documentation As Per Engineer In Charge And As Per Special Condition Of The Contract. Note - 1 Job Equal To Acmc Of 1 No Split Ac (1.0 Tr/1.5 /2.0 Tr) For 1 Year. Second Year" "annual Comprehensive Maintenance Of 1.5 Tr & 2.0 Tr Window Type Air Conditioners Of M/s Hitachi/o-general Make Installed At Different Locations Of Kushinagar International Airport As Mentioned In Appendix I. Works Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Ac Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Handset Say Remote, Thermostats, Capacitors, Selector Switches, Expansion Valve Etc. And Maintaing Records/ Documentation As Per Engineer In Charge And As Per Special Condition Of The Contract. Note - 1 Job Equal To Acmc Of 1 No. Window Ac (1.5 /2.0 Tr) For 1 Year. First Year" "annual Comprehensive Maintenance Of 1.5 Tr & 2.0 Tr Window Type Air Conditioners Of M/s Hitachi/o-general Make Installed At Different Locations Of Kushinagar International Airport As Mentioned In Appendix I. Works Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Ac Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Handset Say Remote, Thermostats, Capacitors, Selector Switches, Expansion Valve Etc. And Maintaing Records/ Documentation As Per Engineer In Charge And As Per Special Condition Of The Contract. Note - 1 Job Equal To Acmc Of 1 No. Window Ac (1.5 /2.0 Tr) For 1 Year. Second Year" "annual Comprehensive Maintenance Of 4.0 Tr (inverter Type) Tower Air Conditioners Of M/s Blue Star / Haier /carrier Etc Make Installed At Atc Tower Of Kushinagar International Airport As Mentioned In Appendix I. Works Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Ac Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Handset Say Remote, Thermostats, Capacitors, Selector Switches, Expansion Valve Etc. And Maintaing Records/ Documentation As Per Engineer In Charge And As Per Special Condition Of The Contract. Note - 1 Job Equal To Acmc Of 1 No. Tower Ac (4.0 Tr) For 1 Year. Second Year" "annual Comprehensive Maintenance Contract Of Existing Oasis Make Recessed Bi-level Drinking Water Fountain, With Double Ss Bubbler And With Mechanical And Sensor Both Through Oem Only Including Servicing, Repairing, Supply And Replacement Of All Spares I/c Refrigerant Gas, Compressor Etc. As Per The Requirement And Quarterly Preventive Maintenance Visits And Breakdown Visits Through Oem/oem Authorized Service Dealer Only Strictly As Per The Scope Of Work Of Special Condition Of Contract. Note - 1) 1 Job Equal To Acmc Of 1 No. Drinking Water Fountain With Inbuilt Ro For 1 Year. 2) In This Item, The Replacement Of Consumables Like Pf Candle Filter, Block Filter/carbon & Ro Membrane Are Covered Only One Times In A Year. First Year" "annual Comprehensive Maintenance Contract Of Existing Oasis Make Recessed Bi-level Drinking Water Fountain, With Double Ss Bubbler And With Mechanical And Sensor Both Through Oem Only Including Servicing, Repairing, Supply And Replacement Of All Spares I/c Refrigerant Gas, Compressor Etc. As Per The Requirement And Quarterly Preventive Maintenance Visits And Breakdown Visits Through Oem/oem Authorized Service Dealer Only Strictly As Per The Scope Of Work Of Special Condition Of Contract. Note - 1) 1 Job Equal To Acmc Of 1 No. Drinking Water Fountain With Inbuilt Ro For 1 Year. 2) In This Item, The Replacement Of Consumables Like Pf Candle Filter, Block Filter/carbon & Ro Membrane Are Covered Only One Times In A Year. Second Year" Replacement Of Candel 20 Inch /as Per Oem Recommendation And As When Required. (make-oasis) Replacement Of Block 20 Inch /as Per Oem Recommendation And As When Required. (make-oasis) Replacement Of Pf Candel 20 Inch /as Per Oem Recommendation And As When Required. (make-oasis) Replacement Of Gac Filter 20 Inch /as Per Oem Recommendation And As When Required.(make-oasis) "replacement Of Membrane /as Per Oem Recommendation And As When Required (make-oasis) " "annual Comprehensive Maintenance Contract Of 80 Ltrs/hr Water Coolers With Inbuilt Water Purifier (ro Plus Uv) Having Storage Capacity Of Blue Star/cilmatrol Etc.make At Different Locations Of Kushinagar International Airport. Work Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Water Cooler With Ro Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Thermostats, Capacitors, Solenoid Valve Etc. Through Oem Or Authorized Oem Service Dealer And Maintaing Records/ Documentation As Per Engineer Incharge And As Per Special Condition Of The Contract. Note - 1) 1 Job Equal To Acmc Of 1 No. Water Cooler With Inbuilt Ro For 1 Year. 2) In This Item, The Replacement Of Consumables Like Pf Candle Filter, Block Filter/carbon & Ro Membrane Are Covered Only One Times In A Year. First Year" "annual Comprehensive Maintenance Contract Of 80 Ltrs/hr Water Coolers With Inbuilt Water Purifier (ro Plus Uv) Having Storage Capacity Of Blue Star/cilmatrol Etc.make At Different Locations Of Kushinagar International Airport. Work Include Carrying Out Quarterly Visit For Servicing And Maintenance Of Water Cooler With Ro Units Including Attend To Complaints / Faults / Breakdowns And Taking Rectification Action Ensuring Serviceability/satisfactory Working Condition Of The Systems And Also Includes Refrigerant Gas Charging And Repair/replacement Of Required Spares Parts Like Pcbs, Refrigerrant Pipe, Compressors, All Type Of Relays, Motors, Thermostats, Capacitors, Solenoid Valve Etc. Through Oem Or Authorized Oem Service Dealer And Maintaing Records/ Documentation As Per Engineer Incharge And As Per Special Condition Of The Contract. Note - 1) 1 Job Equal To Acmc Of 1 No. Water Cooler With Inbuilt Ro For 1 Year. 2) In This Item, The Replacement Of Consumables Like Pf Candle Filter, Block Filter/carbon & Ro Membrane Are Covered Only One Times In A Year. Second Year" Replacement Of Block/carbon Filter 10 Inch For The Inbuilt Water Purifier Or As Per Oem Recommendation As And When Required. Replacement Of Pf Candel Filter 10 Inch For The Inbuilt Water Purifier Or As Per Oem Recommendation As And When Required. Replacement Of Membrane Filter For The Inbuilt Water Purifier Or As Per Oem Recommendation As And When Required. Dismantling Of Existing Split A.c/window A.c/tower A.c Of Different Rating / Capacity Up To 4 Tr From Existing Site Including Dismantling Of Stand, Stabilizer & Other Associated Accessories Etc, Refilling Existing Holes, Plastering, Finishing The Walls, Shifting Of The Removed Air Conditioning Unit Along With The Accessories Up To Store Room As Per The Direction Of Engineer Incharge And As Per Site Requirement. Installation Testing And Commissioning Of Split A.c/window A.c/tower A.c Of Different Rating /capacity Up To 4 Tr Including Making Holes, Plastering, Refrigerant Gas Charging, Connection With 4 Sq Mm Copper Power Input Cable From Nearest Power Outlet, Testing & Commissioning Etc As Per Site Requirement And As Per The Direction Of The Engineer In Charge. Supply And Installation Of Copper Refrigerant Pipe ( 1/2 Inch Plus 1/4 Inch ) Complete With Fitting Suction Line, Discharge Line With 12 Mm Thick Nitrile Rubber Insulation Between Indoor Unit & Outdoor Unit, Brazing Including Providing Of Clamps, Testing & Commissioning Etc. Complete As Required For 1.0/1.5 Tr Split Ac. Supply And Installation Of Copper Refrigerant Pipe ( 5/8 Inch Plus 3/8 Inch ) Complete With Fitting Suction Line, Discharge Line With 19 Mm Thick Nitrile Rubber Insulation, Brazing Including Providing Of Clamps Etc. Complete As Required For 2.0 Tr Split Ac. Supply And Installation Of Rigid Pvc/flexible Drain Pipe Of 25 Mm Dia With 6mm Heatlon/teflon Insulation Complete With Fittings & Accessories, U Straps Etc. Supplying & Fixing Of Approved Make Electrical Cable 3 Core X 2.5 Sq.mm Suitable For 1.5 / 2.0 Tr Split Airconditioning Unit With Accessories Complete As Required. Providing And Fixing 12 Mm Nitrile Rubber Insulation On The Suction And Discharge Line Of The Existing Split Air Conditioners As Required. Providing And Fixing 19 Mm Nitrile Rubber Insulation On The Suction And Discharge Line Of The Existing 2.0 Tr Split Air Conditioners As Required.

Ref. Document
View Tender
#TBR: 34394226 Closed

Telecommunication Services And Equipments

  • Bihar
  • Due On: 08 May, 2025 (0 Days Left)

Gem Bids For 100 Supply Supply Of Sac Supply Of Ac Sac Unit Supply Airconditioning

Ref. Document
View Tender
#TBR: 32850268 Closed

Telecommunication Services/equipments

  • Delhi
  • Due On: 26 Sep, 2024 (0 Days Left)

Essential Work Of Airconditioning Unit Installed At Various Te Building / Rsu Sites Under Ee E Bcp,

25.96 Lacs
View Tender
#TBR: 32588086 Closed

Construction

  • Maharashtra
  • Due On: 26 Aug, 2024 (0 Days Left)

Providing Renovation To Electrical Installation With Airconditioning Unit In Auditorium On 6Th Floor Main Building

17.12 Lacs
View Tender
#TBR: 32214861 Closed

Construction

  • Maharashtra
  • Due On: 19 Jul, 2024 (0 Days Left)

Providing Renovation To Electrical Installation And Airconditioning Unit In Department Of Cooperative Marketing And Textile Industry On 3Rd And 14Th Floor

45.28 Lacs
View Tender
#TBR: 32180470 Closed

Construction

  • West Bengal
  • Due On: 22 Jul, 2024 (0 Days Left)

Supply, Installation And Commissioning Of 03 Nos Of 11Tr Fixed Speed Ceiling Mounted Ductable Split Type Airconditioning Unit For Esp Control Room Of Unit 7

Ref. Document
View Tender
#TBR: 31013277 Closed

Scientific Research And Instruments

  • Maharashtra
  • Due On: 29 Feb, 2024 (0 Days Left)

Custom Bid For Services - Comprehensive Maintenance Contract For Compressed Air Dryers Chiller Unit Airconditioning Units And Water Coolers For Three Years

5.00 Lacs
View Tender
#TBR: 29910597 Closed

Construction

  • Maharashtra
  • Due On: 07 Nov, 2023 (0 Days Left)

Providing Renovation To Electrical Installation And Airconditioning Unit In Enviroment Department On 15Th At New Administrative Building

34.76 Lacs
View Tender
#TBR: 29784605 Closed

Construction

  • Maharashtra
  • Due On: 25 Oct, 2023 (0 Days Left)

Revised Providing Renovation To Electrical Installation And Airconditioning Unit In Enviroment Department On 15Th At New Administrative Building

34.76 Lacs
View Tender
Download Document