Supply Of Supply Of Tool Boxes For Electric Locomotives As Per Annexure - Bdl/2025/tool Box Attached. Dimension Of Box L X W X H:- 28 Cm X 15 Cm X 38 Cm. Material Of The Box: Crc Metal Sheet 18 Gauge Is: 513 Of 2008 And Boxes To Be Painted With Polish Powder Coated Duly Cured At Heated Chamber..
Gem Bids For Ms Perforated Sheet Crc Round Hole Size 1250 X 2500mm Hole Diameter- 5.0mm Ms Perforated Sheet Crc Round Hole Size 1250 X 2500mm Hole Diameter- 6.0mm Ms Perforated Sheet Crc Round Hole Size 1250 X 2500mm Hole Diameter- 8.0mm Ms Perforated Sheet Crc Capsule Hole Size 1250 X 2500mm Hole Diameter- 3.0x20 Mm Long Ms Perforated Sheet Crc Capsule Hole Size 1250 X 2500mm Hole Diameter- 1.8x20 Mm Long
Water Proofing Of Seed Processing Plant Through Gs Sheet At Crc
Supply of Combination Fuse Switch Units, Rated Current 200 Amp, Metal Clad, Triple Pol E With Neutral Link, Degree Of Protection Ip - 2L3, As Per Is/Iec 60947Part -1/2004 & Is/Iec 6 0947Part-3/1999 Quick Make & Break, Interlockable Cover, Uninterrupted Duty Utilazati On Category Ac-23 A With Three Number High Rupturing Capacity80 Ka Minimumcartridge Fuses With Bolted Connection Rated Voltage 415 Volt 50 Hz Ac Confo Rming To Is:13703Pt.I/1993Reaffirmed 2004 & Is:13703 Pt.2/Section 1 & 2/1993 Reaffirme D 2004, Enclosure Shall Be Made Of Crc Sheet Of Thickness Not Less Than 1.2 Mm. Warra Nty Period: 30 Months After The Date Of Delivery
Supply of 20 Pair Cable Termination Box As Per Following Specification And Attached Drawing.1 The Size Of The Box Should Be 243Mm H X 130Mm W X 100Mm D.2 The Ct Box Should Be Made Of 16 Swg Crc Sheet.3 The Ct Box Should Be Grey Colour Powder Coated.4 Terminal With Washer, Nut & Bolt Shou Ld Be Of Brass And Should Be In Matrix 10 X 4 I.E. Each Column Should Have 10 Terminals At Equal Interval. The Spacing Between 2Nd And 3Rd Column Should Be Slightly Higher Than The Remaining Column Spacing.5 Brass Terminal Shall Be Terminated On Hylum Sheet Of Minimum 3Mm Thick.6 There Shall Be A Cable Entry Point Made Of Ms Pipe Of Dia. 25Mm And Length 50Mm At The Bottom Of The Box About 25Mm From The Base.7 There Shall Be Also A Cable Entry Point A T The Both Lower Side End Of The Box Of Dia. 20Mm. Both The Cable Entry Point Shall Be Provided With Rubber Grommet.8 There Shall Also Be Locking Arrangeme Nt. The Supplier Should Supply A Sample And Should Get It Approved Before Supplying The Total Quantity. Warranty Period: 12 Months After The Date Of Deliv Ery
Supply of Combination Fuse Switch Units, Rated Current 200 Amp, Metal Clad, Triple Pol E With Neutral Link, Degree Of Protection Ip - 2L3, As Per Is/Iec 60947Part -1/2004 & Is/Iec 6 0947Part-3/1999 Quick Make & Break, Interlockable Cover, Uninterrupted Duty Utilazati On Category Ac-23 A With Three Number High Rupturing Capacity80 Ka Minimumcartridge Fuses With Bolted Connection Rated Voltage 415 Volt 50 Hz Ac Confo Rming To Is:13703Pt.I/1993Reaffirmed 2004 & Is:13703 Pt.2/Section 1 & 2/1993 Reaffirme D 2004, Enclosure Shall Be Made Of Crc Sheet Of Thickness Not Less Than 1.2 Mm. Warra Nty Period: 30 Months After The Date Of Delivery
Supply of Combination Fuse Switch Units, Rated Current 200 Amp, Metal Clad, Triple Pol E With Neutral Link, Degree Of Protection Ip - 2L3, As Per Is/Iec 60947Part -1/2004 & Is/Iec 6 0947Part-3/1999 Quick Make & Break, Interlockable Cover, Uninterrupted Duty Utilazati On Category Ac-23 A With Three Number High Rupturing Capacity80 Ka Minimumcartridge Fuses With Bolted Connection Rated Voltage 415 Volt 50 Hz Ac Confo Rming To Is:13703Pt.I/1993Reaffirmed 2004 & Is:13703 Pt.2/Section 1 & 2/1993 Reaffirme D 2004, Enclosure Shall Be Made Of Crc Sheet Of Thickness Not Less Than 1.2 Mm. Warra Nty Period: 30 Months After The Date Of Delivery
Supply of 1Combination Fuse Switch Units, Metal Clad, Tripple Pole With Neutral Link, Degree Of Pr Otection Ip-2L3 As Per Is:13947 Pt.1/1993, Reaffirmed-2004 Quick Make And Break, Interlockable Co Ver, Uninterrupted Duty, Utilization Category Ac-23A And Confirming To Is:13947 Pt.3/1993, Reaffirme D-2004. It Shall Be Suitable For Three Number High Rupturing Capacity Equal To 80 Ka Hrc Cartridge F Uses Conforming To Is:13703 Pt.1/1993, Reaffirmed-2004 And Is:13703 Pt.2/Section 1 And 2/1993 Reaffirmed-2004 Having Rupturing Capacity 80 Ka Minimum, Rated Voltage 415 Volt, 200 Amp, 50 Hz Ac. As Per Drg.No. 2Enclosure Shall Be Made Of Crc Sheet Of Thickne Specn: 5The Supplier Shall Fur Nish Complete And Satisfactory Type Test Certificate From Any Govt. Laboratory For All The Quoted Item A S Per T/E Specification To The Concern Inspecting Agency At The Time Warranty Period: 30 Months Af Ter The Date Of Delivery
Purchase Of Various Types Of Angles Channels Crc Sheet Etc
Supply of Metal Enclosure Box Made Of Minimum 1.0 Mm Thick Sheet Steel With Crc Powder Coating Suitabl E For Mounting Of Four Pole 250 A Mccb. Make Required: Standard, Abb, Benlo Bentec, Indoasian, H Avells, Hpl, L&T, C&S, Siemens, Legrand, Scheneider, And Axion Only. Warranty Period: 12 Mon Ths After The Date Of Delivery