Tender Bharat Website covers all Tenders for led street light repair – Including led street light repair Government Tenders, e Tender led street light repair, led street light repair Tenders and Private Tenders. There is no shortage of business opportunities from the largest led street light repair Tender Database.
Our website allows you to find led street light repair tenders online quickly and easily. Subscribers can also opt to receive daily tender alerts through email from TenderBharat.com to guarantee they don't miss out on any opportunities.
Supply of Taking down of fittings of any type size and model complete all as specified , Taking down of brackets of any type size and model complete all as specified , M and L in steel tubular swaged poles complete with cast iron base plate finial taper plug , M and L in steel tubular swaged poles complete with cast iron base plate, finial taper plug , Re fixing of fittings of any wattage outdoor type complete all as specified and directed. , S and F in fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing , Supply and fixing in flood 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped , S and F in flood 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped , S and F Cable Junction Box 155X210X92 mm in size, made out of thermoplastic having IP 66 protection for outdoor installation fixed with 4 way , Supply and passing through steel tubler pole service connection 1100 volts grade multicore FR round insulated copper conductor , S and F single arm bracket made of 40mm dia 1.0mtr long for security with mounting MS clamp , S and F in Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all , M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground , Taking down out unservicable or servicable UG cable of any cross section area and connection etc. , Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth , Returning Filling in including Spreading, Levelling Watering and Well Ramming in Layers not exc. , Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. , M and L Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable , M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable , S and L for cable in trenches or passing through pipe, XLPE insulated 25 sqmm 4 core. , S and L for cable in trenches or passing through pipe, XLPE insulated, heavy duty, galvanised steel strip or wire armoured electric LT cable 10 sqmm 4 core. , Re laying fixing or passing through XLPE insulated armored electric power UG cable etc. , S and F 40 mm High density polyethylene pipe HDPE of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. complete all as specified and directed . , S and F Galvanised Iron Pipe 40mm Bore dia Grade for protection of UG Cable laid in Floors , Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path, not exc. 10.00 mtr , M and L for PCC 1.2.4 type B1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces , M and L for PCC 1.3.6 type C2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed. , S and F HDPE DWC Double Wal Corrugated of Diameter 25 mm including disconnection and connection of cable. , M and L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn , Wrecking Crow Bar or Claw Bar as per IS 706 (Q3)
Taking down of fittings of any type size and model complete all as specified and directed. , Taking down of brackets of any type size and model complete all as specified and directed. , M and L in steel tubular swaged poles complete with cast iron base plate finial taper plug bolts , M and L in steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts and screws , Re fixing of fittings of any wattage outdoor type complete all as specified and directed. , Supply and fixing in fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum , S and F in flood 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped , S and F in flood 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 , S and F Cable Junction Box 155X210X92 mm in size made out of thermoplastic having IP 66 protection for outdoor installation fixed with 4 way bakelite , Supply and passing through steel tubler pole service connection 1100 volts grade multicore FR round insulated copper conductor and sheathed flexible , S and F single arm bracket made of40mm dia 1.0mtrs long for security , S and F in Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all tees , M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground , Taking down out unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks , Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth Taking Out and Laying of Cables etc , Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in Soft Loose Soil , Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed. , M and L Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread , M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. , Supply and laying for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable , Supply and laying for cable in trenches or passing through pipe XLPE insulated heavy duty 10 sqmm 4 core. , Re Laying Fixing or Passing through Pipe XLPE insulated Armoured Electric Power UG Cable , S and F 40 mm High density polyethylene pipe HDPE of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. , S and F Galvanised Iron Pipe 40mm Bore dia Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole etc. , Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc. 10.00 mtr , M and L for PCC 1.2.4 type B1 using 20 mm graded aggregate as in coping for pole including form work and finishing the surfaces , M and L for PCC 1.3.6 type C2 using 40 mm graded aggregate as in foundation for pole etc , S and F HDPE DWC Double Wal Corrugated of Diameter 25 mm including disconnection and connection , M and L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn , Overload Relay (Q3) , Compression cable lugs (Q3)
Providing Of 20 Mtr. Long High Mast With Fittings On Yard And Of With Fittings In Ngm Ajitwal Under Market Committee Ajitwal Distt. Moga. Work Code-Ee-E-Fzr-2025-21
20 W Bulb And Maintanence
Supply of Taking down of fittings of any type size and model complete all as specified. , Taking down of brackets of any type size and model complete all as specified and directed. , M and L in steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts , M and L in steel tubular swaged poles complete with cast iron base plate , Re fixing of fittings of any wattage outdoor type complete all as specified and directed. , Supply and fixing in fitting 120 Watt 230 V AC outdoor type , Supply and fixing in flood 80 watt 230 V AC outdoor type with thermal management in multiple optics , Supply and fixing in flood 150 watt 230 V AC outdoor type with thermal management , S and F Cable Junction Box 155X210X92 mm in size made out of thermoplastic aving IP 66 protection , Supply and passing through steel tubler pole service connection 1100 volts grade multicore FR round insulated copper conductor , S and F single arm bracket made of 40mm dia 1.0mtr long for security with mounting MS clamp , S and F in Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes junction terminal , M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs , Taking down out unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks GI Pipe etc. , Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth Taking Out and Laying of Cables etc. , Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in Soft Loose Soil complete all as specified , Removing excavated Materials Soils not exc. 50.00 mtr , M and L Sand Cushioning dry in Trenches for protec tion of UG Cables , M and L for fly ash bricks locally available laid dry width wise across the line of cable , Supply and laying for cable in trenches or passing through pipe XLPE insulated heavy duty , Supply and laying for cable in trenches or passing through pipe XLPE insulated 10 sqmm 4 core. , Re Laying Fixing or Passing through Pipe XLPE insulated Armoured Electric Power UG Cable 10 Sqmm 2 Core to 25 Sqmm 4 Core , S and F 40 mm High density polyethylene pipe HDPE of pressure rating 6 kgf cm2 fixed complete to walls , S and F Galvanised Iron Pipe 40mm Bore dia Grade for protection of UG Cable laid in Floors , Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore , M and L for PCC 1.2.4 type B1 using 20 mm graded aggregate , M and L for PCC 1.3.6 type C2 using 40 mm graded aggregate as in foundation for pole etc complete , S and F HDPE DWC Double Wal Corrugated of Diameter 25 mm including , M and L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground , Crimping Tools (Q3)
Maintenance Of Summer Cooling Appliances Water Heater Connected Items Maintenance Replacement Of Allied Works And Replacement Of Allied Works Of Certain Unit At Misa Camp Under Ge S Tezpur
And Maintenance Of , Flood , Gate And Other Connected Works At Ins Agrani
Supply of Taking down of fittings of any type size and model complete all as specified , Taking down of brackets of any type size and model complete all as specified , M and L in steel tubular swaged poles complete with cast iron base plate finial taper plug bolts nuts and screws as specified , Re fixing of fittings of any wattage outdoor type complete all as specified and directed. , S and F in fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing. , S and F in flood 80 watt 230 V AC outdoor type with thermal management in multiple optics and equipped , S and F in flood 150 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection , S and F Cable Junction Box 155X210X92 mm in size made out of thermoplasti having IP 66 protection for outdoor installation fixed with 4 way bakelite cable terminals , Supply and passing through steel tubler pole service connection 1100 volts grade multicore FR round insulated copper conductor , S and F single arm bracket made of 40mm dia 1.0mtr long for security with mounting MS clamp , S and F in Rigid non metallic PVC conduit of dia 20 mm exclusive of boxes junction terminal but inclusive of all tees bends elbows , M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground , Taking down out unserviceable or serviceable UG Cables of any Cross Sectional Area and Connections including Bricks , Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth Taking Out and Laying of Cables etc. , Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm , Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above , M and L Sand Cushioning dry in Trenches for protection of UG Cables , M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable , S and L for cable in trenches or passing through pipe XLPE insulated wire armoured electric LT cable 25 sqmm 4 core. , S and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable a 10 sqmm 4 core. , ReLaying Fixing or Passing through Pipe XLPE insulated Armoured Electric Power UG Cable Heavy Duty , S and F 40 mm High density polyethylene pipe HDPE of pressure rating 6 kgf cm2 fixed complete to walls ceilings or in floors etc. , S and F Galvanised Iron Pipe 40mm Bore dia Grade for protection of UG Cable laid in Floors , Labour only for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia , M and L for PCC 1.2.4 type B1 using 20 mm graded aggregate as in coping for pole including form work and finishing , M and L for PCC 1.3.6 type C2 using 40 mm graded aggregate as in foundation for pole etc complete all as specified and as directed. , S and F HDPE DWC Double Wal Corrugated of Diameter 25 mm including disconnection and connection of cable , M and L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground , Wrecking Crow Bar or Claw Bar as per IS 706 (Q3)
Supply And Fixing Of 03 Nos. Water Cooler With Access, Rep / Exte Of L.t. Line, Pole Painting, Tighte Of Over Head Line Guardi Of , Repa Of 2 Nos. High Mast With Old Flood Driver And Inte Elect In Mandi Office At Nmy Khalilabad
Operation And Maintenance Of Electrical Systemselectrical Installations - Of Unserviceable With Smart At Jaipur Mil Stn