Gem Bids For Wall Tiles 30cm X 30cm, Floor Tiles 30cm X 30cm Non -skid, Aluminum Door Size 3ft 3inch X6ft 6inch And 30 Mm Thickwith Frame, Floor Tiles 60cm X 60cm, White Cement, Exhaust Fan Size 12inch, Mirror Size 12inch X 18inch Withframe, Square Box Pipe 1.5ft X 1.5ft 6 Mtr Long For Maingate, Gi Elbow 15mm, Bibcock 15 Mm, Cp Angle Cock 15mm, Gi Socket 15mm, Gi Nipple 15 Mm Dia 6inch Long, Ginipple 15 Mm Dia 4 Inch Long, Gi Nipple 15 Mm Dia 3 Inchlong, Gi Nipple 15 Mm Dia 2 Inch Long, Gi Nipple 15 Mm Diahalf Inch Long, Cp Floor Jaali 4 Inch, Nahani Trap 2.5 Inch, Gi Pipe 15 Mm, Wc European Type, Wc Sheet Cover, Cistern 10 Ltr Cap, Nozzle Jet Spray For Toilets 15 Mm, Handjet Spray, Cp Angle Cock Two In One 15 Mm, Pvcconnection Pipe 15mm, Pvc Pipe 4 Inch Dia 6 Mtr Long, Pvc Bend 4 Inch Dia, Pvc Socket 4 Inch Dia, Pvc Pipe 2.5inch Dia 6 Mtr Long, Pvc Bend 2.5 Inch Dia, Pvc Socket 2.5inch Dia, Pvc Tee 2.5 Inch Dia, Man Hole Cover 2 Ft X 2 Ft, Ms Hook, Fevicol Sr 500 Gm Packet, Plumbing M Seal 250gm Pack, M Seal 250 Gm Pack, Wash Basin With Fullpedestal, Wash Basin Bracket, Cp Pillar Cock 15mm Forwash Basin, Pvc Waste Pipe, Cp Coupling, Floor Jaalicentre Hole 4 Inch, Gi Tee 15 Mm, Gi Tee 25x15mm, Giunion 15mm, Gi Gate Valve 20mm Brass, Tank Nipple, Gireducer 25x15mm, Ball Cock 15 Mm, Cp Cap, Pvc Copperwire 2.5 Sqmm, Pvc Copper Wire 1.5 Sqmm, Powercombined Box 16 Amp, Switch 6 Amp, Socket 6 Amp, Ledtube 20 Watt, Button Holder, Mcb 16 Amp, Led Bulb 9 Watt, Casing Caping 1.5 Inch, Mcb 10 Amp, Pvc Gang Box 3way, Pvc Gang Box 6 Way, Pvc Square Box 4 Inch X4 Inch, Aluminum Cable 10 Sqm 90 Mtr, Gi Mcb Box 4 Way, Ledflood Light 100 Watt, Casing Bit Screw
Gem Bids For Ms, Bid Number Gem2025b6677453 Dated 20-09-2025 Bid Document1 55 0 0 Ms Sheet With Hole 60 Mm, Ms Sheet With Hole 25 Mm, Freezer, Distemper White, Brush 4 Inch, Brush 9 Inch, Wall Tiles, White Cement, Scantling 12 Ft, Scantling 10 Ft, Nails, Ac Sheet, Urinal Pot, Switch Socket, Pvc Switch 1Way, Pvc Switch 2 Way, Pvc Switch 4 Way, Pvc Switch 6Way, Floor Tiles, Wooden Door, Aluminum Door, Tubelight 18W, Led Bulb, Led Bulb 7W, Led Bulb 9 W, Ledbulb 15 W, Led Holder, Pvc Holder, Tube Light Led 20W, Tube Light Led 40W, Pvc Sadal, Insulation Tape, Socket 6Amp, Switch 6 Amp, Switch Socket 6 Amp, Switch Socket10 Amp, Switch Socket 16 Amp, Three Pin Plug 6 Amp, Three Pin Plug 16 Amp, Pvc Copper Wire Conductor 1Sqmm Single Core, Pvc Copper Wire Conductor 1 Pt 5Sqmm Single Core, Pvc Copper Wire Conductor 1 Pt 5Sqmm Double Core, Pvc Copper Wire Conductor 2 Pt 5Sqmm Single Core, Pvc Copper Wire Conductor 2 Pt 5Sqmm Double Core, Pvc Casing Caping 2Inch 3 Mtr Long, Pvc Casing Caping 1 Pt 5Inch 3 Mtr Long, Mcb 10 Amp, Mcb 16 Amp, Mcb 32 Amp, Mcb Box 6 Way, Mcb Box 8Way, Change Over Switch 100 Amp, Screw 0 Pt 5Inch Pkt Of100 Piece, Screw 1Inch Pkt Of 100 Piece, Screw 1 Pt 5Inchpkt Of 100 Piece, Screw 2Inch Pkt Of 100 Piece, Copperwire, Ceiling Fan, Casing Capping, Pvc Pipe Half Inch, Pvc Modular Board 6 Module, Pvc Modular Board 2 Module, Pvc Modular Board 8 Module, Pvc Modular Bell Switch, Pvc Modular Board 1 Module, Pvc Modular Switch 6A, Pvcmodular Socket 6A, Pvc Modular Switch 16 A, Pvc Modularswitch Two Way 6 A, Colour Bulb 5W, Focus Light 3W, Bulb For Wall Mounted Lamp 9W, Wc Indian Sheet, Watermixture Tap, Wash Hand Basin, Water Tank 1000 Ltr, Water Tank Stand, Water Pump 0 Pt 5 Hp, Steel Cock, Wallputty, Damp Proof Paint, Paint Brush 100 Mm, Paint Brush75 Mm, Paint Roller 9Inch, Wall Putty Blade, Termite Pastcontrol, Wall Mounted Lamp
Gem Bids For Borewell, Distribution Box 6 Way Double Door Spn 240 Volts Copperbus Bar And Neutral Link Earthing Stud Conforming To Is13032 And Is 8623 Double Door Type Of Make Havellslegrand L And T., Mcb Spn 240 Volts 32 Amps Of Makehavells L And T Finolex Standard, Mcb Sp 6 To 32 Amps Ofmake Havells L And T Standard, Pvc Tape 19mm Wide 5mlong Of Isi Marked, Pvc Insulated Elec Cables Heavy Duty1100 Volts Gde Multi Stranded Copper Conductor Of Size 1.5sqmm Single Core Frls Confirming To Is 1554 Part 1 1988 Of, Pvc Insulated Elecric Cables Heavy Duty 1100 Volts Grademulti Stranded Copper Conductor Of Size 2.5 Sqmm Singlecore Frls Confirming To Is 1554 Part 1 1988 Of Make Havellsfinolex And Polycab., Pvc Casing Capping Of Size 1 Inchmedium Grade Snow White Of Make Presto Polycab Andfinolex., Pvc Casing Capping 3 Of 4 Inch Medium Gradesnow White Of Make Presto Polycab And Finolex., Switchpiano 5amp 230v Flush Type One Way Snow White Of Makeanchor Ssk And Cona, Led Tube Light Fittings 15w 230vbox Type 4 Feets With Crca Body Pre Coated White Andprewired For Led Tuble Complete Of Make Havells Bajajphilips And Crompton, Switch Socket Combination Snowwhite Multipurpose 2 In 1 15 Amp 230 Volts Of Make Havellsfinolex Polycab Natural White Or Equivalent., Switch Socketcombination Snow White 5 Amp 230 Volts Of Make Anchorssk And Finolex., Pvc L Bend And T Junction Joint For Pvccasing And Caping Conforming To Is-3419 Part-iii Of Makesupreme Polycab And Finolex, Switch Socket Combinationsnow White Multipurpose 2 In 1 15a 230 Volt Make Anchorssk Cona, Switch Socket Combination Snow White 5a 230volt Make Anchor Ssk Cona, Service Bracket 40mm Dia Gitubing Medium Grade 1.5m Long Make Jindal Tata Kalinga., Service Cable Pvc Insulated Aluminium Conductor 1100 Voltgde Hy Duty Served With Inner Sheathing Of Pvc Tap And /bid Number: Gem/2025/b/6702004* /dated: 19-09-2025 & & / Bid Document1 / 38 & & /item Categoryoverall Pvc Sheathed In Service Connection 10 Sqmm 2core., Ceiling Rose Three Terminal Snow White Make Anchorssk Cona, Led Bulk Head Fitting High Pressure Die Castaluminum Front Cover With Glass Cover With Specially Designgasket With Led Lamp 10 Watts Make Havells Bajaj Philipscrompton, Pvc Flexible Wire Copper Conductor Multistranded 0.0016 76 Make Havells Finolex Plaza, Pvcflexible Conduit Pipe 15mm Dia Make Polycab Supremefinolex, Pvc Round Square Block Make Polycab Supremefinolex, Fire Extinguisher Of One Kilogram Capacity Drypower Type Conforming To Is 13849 Along With Itsaccessories Make Cease Fire Omex Alfa Fire., Earthing Plate600 X 600 X 6mm Galvanised Steel Suitable For Gi Stripfittings Drilled With Two Nos Holes For 6 Mm Dia Near Oneside., Ci Earthing Pit Cover Of Size 300x300x6mm With Angleiron Isa 20x20x3mm Thick Ms Frame, Funnel Fitted With20mm Dia Gi Pipe 1.5m Long Make Jindal Tata Kalinga, Giwire 4mm Dia For Earthing, Charcoal, Salt Normal, Cementopc 43 Grade Packed In Hdpe Bag Each 50 Kg Wtconforming To Is 8112 To 1989 Make Birla Gold Ambujaultratech, Coarse Sand Free From Vegetation, Coarseaggregate 20mm Graded, Coarse Aggregate 40mm Graded, Supply Of Ro Uv Alongwith Fitting Accessories Installationwith Specification As Per Technical Specifcation Appendix Battached., Water Storage Tank Triple Layer 1000 Ltrsconfirming To Is 12701 1996 Make Sintex Ultrapure Aquapolywell., Fabrication From Structural Steel Section Forstaging Of Water Storage Tank As Per Technical Specificationappendix B Serial Number 3 Attached., Digging Of Bore Well200 Mm Inner Dia In Any Soil All As Per Technicalspecification Appendix C Serial Number 1 Attached., Submersible Motor Horizontal Type 35hp Water Dischargecapacity Min 100000ltrs Per Day With Dol Starter And Waterprofing Cable., Water Contamination Test From Authorisednabl Lab Duly Certified The Purify Of Water Level.
Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50mt. & Lift Of 1.5mtr Etc Complete As Per The Direction Of The Engineer-incharge. Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-incharge. Cement Concrete (1:4:8) With 4cm Size H.g.b. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&p Required Etc. Complete As Per The Direction Of The Engineer-incharge, Cement Concrete (1:2:4) Using 12mm Size Black Hard Granite Crusher Broken Chips Of Approve Quality For Approve Quorry Including Water And Curring With Cost Taxes Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. Brick Work With Fly Ash Brick 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-incharge, Construction And Erection Of 11 /0.4 Kv , 25 Kva Double Pole Mounted Substation Star Rated Confirming To Re Rules 1956, Mounted On 2.44 Mtr. Long Structure, Supported In 400 Kg 10 Mtr Long Psc Pole,transformer Hard Channel & Top Channel Made Of 2.8 M Long 100 X 50 X 6 Mm M.s.channel, Transformer Belting On 2.80 M Long 50 X 50 X 5 Mm M.s.angle, (all Rec Spn Std.f-3) With All Accessories Like 3 Pole 11 Kv Hg Fuse(f-5)& A.b.switches(f-9) Both Mounted On 2.8 M Long 75 X 40 X 6 Mm M.s.channel And Supported By 1.0 M Long 50 X 50 X 5 Mm M.s.angle, With 3 No. 11 Kv Lightening Arrestors & Distribution Box For 25 Kva S/s, G.i.pipe Earthing With 25x5mm G.i.flats Including Cost Of 25 Kva 11/0.4 K.v.transformer , 35 Sqmm 3 1/2 Core Pvc Cable - 40 Mtr Couping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices & All Other Necessary Fittings I.e Required Size Nuts & Bolts, Brackets, Cable, Cable Sockets, Barbed Fencing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Consturction Of Barbed Wall Of Substation Electrical Installation With Electrical Materials Such As Pvc Tape, Ampere Tape, 7/20 Pvc Copper Wire, 3/20 Pvc Copper Wire, G.i. Flexible Conduite Pipe, No.6 G.i. Wire, Copper Cable Socket, G.i. Socket And Flange And Petty Materials Required For Electrical Installation. All Materials Should Be As Per Is. Electrical Earthing With Digging Earth Pit Of Size (2 Ft X 2 Ft X 3 Ft ) And Using 1/2 '' G.i Pipe ,no -6 G.i Wire ,cable Socket ,flange , Carcoal, Salt Etc. As Per The Direction Of The Engineer-incharge. 3 X 2.5 Mm2 S/s Flat Cable
Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50mt. & Lift Of 1.5mtr Etc Complete As Per The Direction Of The Engineer-incharge. Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-incharge. Cement Concrete (1:4:8) With 4cm Size H.g.b. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&p Required Etc. Complete As Per The Direction Of The Engineer-incharge. Brick Work With Fly Ash Brick 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-incharge. 12mm Cement Plaster In Cement Mortar (1:6) Finished Smooth To Brick Work After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. R.c.c. Work In C.c. (1:2:4) Including Hoisting & Laying & Curring For 28 Days Using 12mm. Size Clean Black Hard Granite Crusher Broken Chips Of Approve Quality And From Approve Quarry Including Cost Taxes Conveyance Charges Of All Materials To The Worksite With Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. "rigid Smooths Centering And Shuttering For Rcc Works Including False Work And Dismentgalling Then After Casting Including Cot Os Materials Complete. (a) Rcc Walls And Fins Including Attached Pillasters" Labour Charge For M.s. Reinforcement For R.c.c. Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Still Bar (fe 415/ Fe 500) Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-incharge. Finishing Wall With Water Proofing Cement Paint Of Approved Shade Two Coats To New Work To Give An Even Shade Including Cost Of Cement Paints. Etc. Complete As Per The Direction Of Engineer – In Charge. Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-incharge. Supplying Of 160 Mm Dia Unplasticised Rigid Upvc Pipe Ivory Gray In Colour Having Specific Gravity Of 1.40 To 1.46 Gms/cc Of Straight Length Of 6 (six) Meter For Portable Water Supplies Conforming To Is - 4985 / 2000 Of Bis - Amendment - 2 Read With Table - 1 Of Is - Specification Bearing Isi Marks For Working Pressure Ci - I Upvc Pipe To Withstand Pressure Of 2.5 Kgf/sqcm & The Specification And Manufacturer Name Should Be Prominently Marked On Body Of Each Pipe As Per The Latest Amendment Of Is - 4985. It Includes The Cost Of Sockets In Case Of Plain Ended Pipe. Pdi Test ( Both Pre & Post Inspection ) Are To Be Condcuted And Should Be Marked On Body Of Each Pipe And Report Is To Be Obtained From Cipet, Bhubaneswar Necessary Approval Of Authority Including Transportation To Work Site In Complete Shape. Fitting Of Un Plasticised 160mm Dia Pvc Pipe For Following Inside Dia Mtr. For All Classes Of Pipe Including Jointing The Pipe With Solvent Cement By Non-head Application Method Including Fitting And Fixing Of Required No. Of Pvc Tee For Outlet And Pvc Shaddle And Pvc Riser Nipple For Fitting Air Valve, Equal Tee Etc. Complete Including Conveyance Pipe From Village To Worksite And Testing Of Pipe Line Etc. Complete As Per The Direction Of The Engineer-incharge. 7.5 Hp / 5.6 Kw Submersible Pumpset Corpled With Totally Enclosed Water Cooled Squirrel Case Induction Motor With Delivery Discharge 1100 Lpm At 36 Meter Head With S/s Cable, Clamp Clip Etc. Suitable For Operation At 415v + -15%, 3 Phase 50hz A.c. Power Supply As Per Particulars In Annexure. Labour Charges For Installation Of 7.5hp Motor Including Fitting & Fixing Of Base Frame, Fitting & Fixing Suction And Delivery Pipe To Motor, Nr Valve, Foot Valve, Sluice Valve And Other Fitting Materials Including Cutting, Welding And Construction Of Supporting Pillar Etc. Complete As Per The Direction Of The Engineer-incharge. 100 Mm ø Nominal Bore G.i. Pipe Having Wall Thickness 4.5 Mm Electrical Resistance Welded Of Medium Class Confirming To Is - 1239 (pt-1 Of 2004) With Socketed At One End And The Other End Protected With Plastic Thread Protector. The Socket Confirming To Is-1239 (pt-ii/1992) With Latest Amendmewnts In Random Length Of 4 To 7 Mtrs. Each Pipe Should Bear Isi Certification & Manufacturers Name / Trade Mark. 100 Mm Dia G.i. Bend Is No.1239(part-ii/1992) 100 Mm Dia G.i. Flange Is No.6392 / 1971 Cost Of Tw Safe Guard For Stand Includng Labour Charge 100mm Dia Gi Socket Is 1239 (part-ii/1992 ) Cost Of 100 Mm Dia Ms T/w Clamp Cost Of 100 Mm Dia C.i Reflux Valve(nr) 160 Mm X 160 Mm X 160 Mm ø Pvc Equal Tee (w.p. 4 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 160 Mm ø Pvc End Cap (w.p. 10 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 5/8 X3" Nut Bolt & Foundation Nut Bolt As Per Is Specification 1/8" Thick Rubber Insertion As Per Is Specification Cost, Supplying Of 160mmx160mmx110mm Dia Weldless G.i.tee (3.6mm Thickness) With Bend, Closing And Opening Arrangement Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of 160mm×110mm Dia Pvc Reducing Socket. Cost Of 12 Mm Wire Rope Control Pannel With Automatic Star Delta Starter, Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Up To 10 Hp With 16 Amp (ac -3) Duty Contractor At 415 Volt+6%-15%, 3 Phase, 50 Hz Ac Supply With Over Load Relay Range 6.00 To 9.50 Amp & No Volt Coil With Electronic Timer Suitable For Operation At Voltage Range Of 300 To 440 V. The Starter Should Provide Dependable Protection Against Over Load And Single Phasing Fitted With Volt Meter,ameter,mcb In Complete Shape Including Indicator Lamp 63 Amp Main Switch Triple Pole & Neutral Of Voltage Range 440 Volt Of Re-wirable Fuse And Shall Confirm To Is 4064 Part I & With Isi Mark. 3 X 10 Sqmm Tarpodar Cable Xlpe (cross Link Polyethylin) Conforming To Is: 7098 (part-ii) Including Laying Below .9mtr. Of The Ground And Filling The Excavated Materials Including Watering And Ramming. Cost Of Empty Outdoor Irrigation Panel Board (size 0.45mx0.25mx1.20m) Of 18 Swg (cold Rolled) M.s. Sheet With One Coat Of Red Oxid Primer And Two Coats Of Smoke Gray / Navey Blue Enemel Paint On Both Side ( Inside & Outside) Suitable To Mount 3 Phase Starter, Main Switch And Capacitor Inside The Pannel Board Vertically Over 18 Swg M.s. Sheet. The Pannel Board Should Be Provided With Locking Arrangement And Have Grover On Rear Side For Fixing Motor Hood. The Danger Board Should Be Fixed On The To Of The Pannel Door. 2.50mm2 Submerssible (3 Core) Flat Cable Isi Mark Of Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Construction Of 3 Phase 11 Kv Line As Per Rec Standard Confirming To Ie Rules 1956 With 300 Kg 9 M Long Psc Pole With 80 Sqmm Aaac , 11 Kv "v" Cross Arm, With Required No.of 11 Kv T & C Disc. Insulators In Tension Point & 11 Kv Pin Insulators, Couping & Padding Of Poles. Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point & Double Stay At End Point With 18 Mm G.i.h.t.stay, Concreting Of Stay With Anchor Plate, Guarding At Road Crossings Etc. Including Cost Of All Materials, Labour Transportation,inspection & Commissioning Etc. Complete. Construction And Erection Of 11 /0.4 Kv , 25 Kva Double Pole Mounted Substation Star Rated Confirming To Re Rules 1956, Mounted On 2.44 Mtr. Long Structure, Supported In 300 Kg 9 Mtr Long Psc Pole,transformer Hard Channel & Top Channel Made Of 2.8 M Long 100 X 50 X 6 Mm M.s.channel, Transformer Belting On 2.80 M Long 50 X 50 X 5 Mm M.s.angle, (all Rec Spn Std.f-3) With All Accessories Like 3 Pole 11 Kv Hg Fuse(f-5)& A.b.switches(f-9) Both Mounted On 2.8 M Long 75 X 40 X 6 Mm M.s.channel And Supported By 1.0 M Long 50 X 50 X 5 Mm M.s.angle, With 3 No. 11 Kv Lightening Arrestors & Distribution Box For 25 Kva S/s, G.i.pipe Earthing With 25x5mm G.i.flats Including Cost Of 25 Kva 11/0.4 K.v.transformer , 35 Sqmm 3 1/2 Core Pvc Cable - 40 Mtr Couping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices & All Other Necessary Fittings I.e Required Size Nuts & Bolts, Brackets, Cable, Cable Sockets, Barbed Fencing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Construction Of Boundry Wall Fancing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc For Substation As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Electrical Installation With Electrical Materials Such As Pvc Tape, Ampere Tape, 7/20 Pvc Copper Wire, 3/20 Pvc Copper Wire, G.i. Flexible Conduite Pipe, No.6 G.i. Wire, Copper Cable Socket, G.i. Socket And Flange And Petty Materials Required For Electrical Installation Including Fixing Of Td Cable Inside The Earth Trench As Per Direction Of Engineer-in-charge.. Electrical Earthing With Digging Earth Pit Of Size (2 Ft X 2 Ft X 3 Ft ) And Using 1/2 '' G.i Pipe ,no -6 G.i Wire ,cable Socket ,flange , Carcoal, Salt Etc. As Per The Direction Of The Engineer-incharge. 4 Kvr Power Shunt Capasitor 4.0 Mm 2 Pvc Single Core Copper Wire Labour For Drilling A Perfectly Vertical Bore Hole Of Specified Dia For A Specified Depth Below Ground Level In Alluvial Soil Strata By Mud Rotary Rig Drilling As Required To Suit The Site Condition As Per The Direction Of Engineer In Charge Including Use Of Own Rigs With Its Accessories, Tools And Plants And All Consumables (like Coir Rope, Cotton Waste And Bentonite Powder Etc. Complete) Etc. For Lowering Of Finished Bore Suitable For Lowering (minimum 400 Mm Dia.) Of 200mm Dia Gi/pvc Pipe For Housing Fitted With Sockets And With Or Without Well Screen As Per The Necessity For The Soft Medium, Hard And Boulder Formations (. Gi/pvc Casing Pipes If Required By The Contractor To Prevent Collapse Of Over Burden Portion ) Including Lower And Withdrawing Of Casing Pipes After Drilling 200mm To 450mm Dia In Over Burden Portion. For Drilling Of 200 (8”) Dia Pipe. From 0 Mtr. To 100th Meters Supply Of All Labour & T&p For Lowering The Following Sizes Of Pvc Pipes With Or Without Slotted Pipes As Per The Necessity From Ground Level & Fitted & Fixed Up In Perfectly Verticaly Position Inlcuding Cutting & Threading Pipe And Slotted Pipe And Fixing All Jointing Materials Etc. Complete. And Keeping The Top Of The Casing Pipe Threaded Including Plugging Tube Wells To Prevent Entry Of Foreign Materials From Above Excluding Cost Of Fitting & Joining Materials. 200mm Dia Pvc/gi Casing Pipes Cleaning And Developing The Production Well Using Their Own Compressor Continuously Worked Till Clear And Adequate Discharge Is Obtained From The Tube Well Including Supply And Use Of All Necessary Equipments And Labour As Per The Direction Of Engineer-in-charge. Supplying All Materials,labour T & P For Packing The Bore With Washed Gravel Size (p-6) Arround The Well Screen And Pipes In Good Quality Including Cost Of Gravel ,conveyance,royality,etc Complete As Per Direction Engineer-in-charge. (100m Depth) =0.786 X (0.4² - 0.2²) X 100mtr = 9.43 Say 9.5 Cum Supplying All Labour Tools ,plant And Grouting With Cement Bentonite Slurry For Saline Sealing In The Bore Arround 200mm Dia Pvc Casing Pipe Etc All Complete As Per Direction Of Engg In Charge(including Cost Of Cement And Bentonite) Labour Charges For Cutting Transverse Slot On 200 Mm Dia Pvc Pipe With Slot Size 1.5 Mm As Per Specification Threading Charges 8" Pvc Bail Plug 8" Pvc Threaded End Cap Pn-10 200mm X 12" Long Pvc Shot Piece 200mm ø Schedule 80 Casing Pipe (as Per Epm Rate Order No.2877 Dated 05.07.2025) Water Sample Test If Required
Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50mt. & Lift Of 1.5mtr Etc Complete As Per The Direction Of The Engineer-incharge. Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-incharge. Cement Concrete (1:4:8) With 4cm Size H.g.b. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&p Required Etc. Complete As Per The Direction Of The Engineer-incharge. Brick Work With Fly Ash Brick 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-incharge. 12mm Cement Plaster In Cement Mortar (1:6) Finished Smooth To Brick Work After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. R.c.c. Work In C.c. (1:2:4) Including Hoisting & Laying & Curring For 28 Days Using 12mm. Size Clean Black Hard Granite Crusher Broken Chips Of Approve Quality And From Approve Quarry Including Cost Taxes Conveyance Charges Of All Materials To The Worksite With Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. "rigid Smooths Centering And Shuttering For Rcc Works Including False Work And Dismentgalling Then After Casting Including Cot Os Materials Complete. (a) Rcc Walls And Fins Including Attached Pillasters" Labour Charge For M.s. Reinforcement For R.c.c. Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Still Bar (fe 415/ Fe 500) Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-incharge. Finishing Wall With Water Proofing Cement Paint Of Approved Shade Two Coats To New Work To Give An Even Shade Including Cost Of Cement Paints. Etc. Complete As Per The Direction Of Engineer – In Charge. Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-incharge. Supplying Of 160 Mm Dia Unplasticised Rigid Upvc Pipe Ivory Gray In Colour Having Specific Gravity Of 1.40 To 1.46 Gms/cc Of Straight Length Of 6 (six) Meter For Portable Water Supplies Conforming To Is - 4985 / 2000 Of Bis - Amendment - 2 Read With Table - 1 Of Is - Specification Bearing Isi Marks For Working Pressure Ci - I Upvc Pipe To Withstand Pressure Of 2.5 Kgf/sqcm & The Specification And Manufacturer Name Should Be Prominently Marked On Body Of Each Pipe As Per The Latest Amendment Of Is - 4985. It Includes The Cost Of Sockets In Case Of Plain Ended Pipe. Pdi Test ( Both Pre & Post Inspection ) Are To Be Condcuted And Should Be Marked On Body Of Each Pipe And Report Is To Be Obtained From Cipet, Bhubaneswar Necessary Approval Of Authority Including Transportation To Work Site In Complete Shape. Fitting Of Un Plasticised 160mm Dia Pvc Pipe For Following Inside Dia Mtr. For All Classes Of Pipe Including Jointing The Pipe With Solvent Cement By Non-head Application Method Including Fitting And Fixing Of Required No. Of Pvc Tee For Outlet And Pvc Shaddle And Pvc Riser Nipple For Fitting Air Valve, Equal Tee Etc. Complete Including Conveyance Pipe From Village To Worksite And Testing Of Pipe Line Etc. Complete As Per The Direction Of The Engineer-incharge. 7.5 Hp / 5.6 Kw Submersible Pumpset Corpled With Totally Enclosed Water Cooled Squirrel Case Induction Motor With Delivery Discharge 1100 Lpm At 36 Meter Head With S/s Cable, Clamp Clip Etc. Suitable For Operation At 415v + -15%, 3 Phase 50hz A.c. Power Supply As Per Particulars In Annexure. Labour Charges For Installation Of 7.5hp Motor Including Fitting & Fixing Of Base Frame, Fitting & Fixing Suction And Delivery Pipe To Motor, Nr Valve, Foot Valve, Sluice Valve And Other Fitting Materials Including Cutting, Welding And Construction Of Supporting Pillar Etc. Complete As Per The Direction Of The Engineer-incharge. 100 Mm ø Nominal Bore G.i. Pipe Having Wall Thickness 4.5 Mm Electrical Resistance Welded Of Medium Class Confirming To Is - 1239 (pt-1 Of 2004) With Socketed At One End And The Other End Protected With Plastic Thread Protector. The Socket Confirming To Is-1239 (pt-ii/1992) With Latest Amendmewnts In Random Length Of 4 To 7 Mtrs. Each Pipe Should Bear Isi Certification & Manufacturers Name / Trade Mark. 100 Mm Dia G.i. Bend Is No.1239(part-ii/1992) 100 Mm Dia G.i. Flange Is No.6392 / 1971 Cost Of Tw Safe Guard For Stand Includng Labour Charge 100mm Dia Gi Socket Is 1239 (part-ii/1992 ) Cost Of 100 Mm Dia Ms T/w Clamp Cost Of 100 Mm Dia C.i Reflux Valve(nr) 25 Mm ø Air Release Valve With Saddle & Raiser Pipe. The Air Release Valve Shall Confirm To Is 14845 With Isi Mark. 160 Mm X 160 Mm X 160 Mm ø Pvc Equal Tee (w.p. 4 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 160 Mm ø Pvc End Cap (w.p. 10 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 5/8 X3" Nut Bolt & Foundation Nut Bolt As Per Is Specification 1/8" Thick Rubber Insertion As Per Is Specification Cost, Supplying Of 160mmx160mmx110mm Dia Weldless G.i.tee (3.6mm Thickness) With Bend, Closing And Opening Arrangement Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of 160mm×110mm Dia Pvc Reducing Socket. Cost Of 12 Mm Wire Rope Control Pannel With Automatic Star Delta Starter, Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Up To 10 Hp With 16 Amp (ac -3) Duty Contractor At 415 Volt+6%-15%, 3 Phase, 50 Hz Ac Supply With Over Load Relay Range 6.00 To 9.50 Amp & No Volt Coil With Electronic Timer Suitable For Operation At Voltage Range Of 300 To 440 V. The Starter Should Provide Dependable Protection Against Over Load And Single Phasing Fitted With Volt Meter,ameter,mcb In Complete Shape Including Indicator Lamp 63 Amp Main Switch Triple Pole & Neutral Of Voltage Range 440 Volt Of Re-wirable Fuse And Shall Confirm To Is 4064 Part I & With Isi Mark. 3 X 10 Sqmm Tarpodar Cable Xlpe (cross Link Polyethylin) Conforming To Is: 7098 (part-ii) Including Laying Below .9mtr. Of The Ground And Filling The Excavated Materials Including Watering And Ramming. Cost Of Empty Outdoor Irrigation Panel Board (size 0.45mx0.25mx1.20m) Of 18 Swg (cold Rolled) M.s. Sheet With One Coat Of Red Oxid Primer And Two Coats Of Smoke Gray / Navey Blue Enemel Paint On Both Side ( Inside & Outside) Suitable To Mount 3 Phase Starter, Main Switch And Capacitor Inside The Pannel Board Vertically Over 18 Swg M.s. Sheet. The Pannel Board Should Be Provided With Locking Arrangement And Have Grover On Rear Side For Fixing Motor Hood. The Danger Board Should Be Fixed On The To Of The Pannel Door. 2.50mm2 Submerssible (3 Core) Flat Cable Isi Mark Of Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of Wiring Of Pump Chamber Construction Of 3 Phase 11 Kv Line As Per Rec Standard Confirming To Ie Rules 1956 With 300 Kg 9 M Long Psc Pole With 80 Sqmm Aaac , 11 Kv "v" Cross Arm, With Required No.of 11 Kv T & C Disc. Insulators In Tension Point & 11 Kv Pin Insulators, Couping & Padding Of Poles. Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point & Double Stay At End Point With 18 Mm G.i.h.t.stay, Concreting Of Stay With Anchor Plate, Guarding At Road Crossings Etc. Including Cost Of All Materials, Labour Transportation,inspection & Commissioning Etc. Complete. Construction And Erection Of 11 /0.4 Kv , 25 Kva Double Pole Mounted Substation Star Rated Confirming To Re Rules 1956, Mounted On 2.44 Mtr. Long Structure, Supported In 300 Kg 9 Mtr Long Psc Pole,transformer Hard Channel & Top Channel Made Of 2.8 M Long 100 X 50 X 6 Mm M.s.channel, Transformer Belting On 2.80 M Long 50 X 50 X 5 Mm M.s.angle, (all Rec Spn Std.f-3) With All Accessories Like 3 Pole 11 Kv Hg Fuse(f-5)& A.b.switches(f-9) Both Mounted On 2.8 M Long 75 X 40 X 6 Mm M.s.channel And Supported By 1.0 M Long 50 X 50 X 5 Mm M.s.angle, With 3 No. 11 Kv Lightening Arrestors & Distribution Box For 25 Kva S/s, G.i.pipe Earthing With 25x5mm G.i.flats Including Cost Of 25 Kva 11/0.4 K.v.transformer , 35 Sqmm 3 1/2 Core Pvc Cable - 40 Mtr Couping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices & All Other Necessary Fittings I.e Required Size Nuts & Bolts, Brackets, Cable, Cable Sockets, Barbed Fencing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Construction Of Boundry Wall Fancing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc For Substation As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Electrical Installation With Electrical Materials Such As Pvc Tape, Ampere Tape, 7/20 Pvc Copper Wire, 3/20 Pvc Copper Wire, G.i. Flexible Conduite Pipe, No.6 G.i. Wire, Copper Cable Socket, G.i. Socket And Flange And Petty Materials Required For Electrical Installation Including Fixing Of Td Cable Inside The Earth Trench As Per Direction Of Engineer-in-charge.. Electrical Earthing With Digging Earth Pit Of Size (2 Ft X 2 Ft X 3 Ft ) And Using 1/2 '' G.i Pipe ,no -6 G.i Wire ,cable Socket ,flange , Carcoal, Salt Etc. As Per The Direction Of The Engineer-incharge. 4 Kvr Power Shunt Capasitor 4.0 Mm 2 Pvc Single Core Copper Wire Labour For Drilling A Perfectly Vertical Bore Hole Of Specified Dia For A Specified Depth Below Ground Level In Alluvial Soil Strata By Mud Rotary Rig Drilling As Required To Suit The Site Condition As Per The Direction Of Engineer In Charge Including Use Of Own Rigs With Its Accessories, Tools And Plants And All Consumables (like Coir Rope, Cotton Waste And Bentonite Powder Etc. Complete) Etc. For Lowering Of Finished Bore Suitable For Lowering (minimum 400 Mm Dia.) Of 200mm Dia Gi/pvc Pipe For Housing Fitted With Sockets And With Or Without Well Screen As Per The Necessity For The Soft Medium, Hard And Boulder Formations (. Gi/pvc Casing Pipes If Required By The Contractor To Prevent Collapse Of Over Burden Portion ) Including Lower And Withdrawing Of Casing Pipes After Drilling 200mm To 450mm Dia In Over Burden Portion. For Drilling Of 200 (8”) Dia Pipe. From 0 Mtr. To 100th Meters Supply Of All Labour & T&p For Lowering The Following Sizes Of Pvc Pipes With Or Without Slotted Pipes As Per The Necessity From Ground Level & Fitted & Fixed Up In Perfectly Verticaly Position Inlcuding Cutting & Threading Pipe And Slotted Pipe And Fixing All Jointing Materials Etc. Complete. And Keeping The Top Of The Casing Pipe Threaded Including Plugging Tube Wells To Prevent Entry Of Foreign Materials From Above Excluding Cost Of Fitting & Joining Materials. 200mm Dia Pvc/gi Casing Pipes Cleaning And Developing The Production Well Using Their Own Compressor Continuously Worked Till Clear And Adequate Discharge Is Obtained From The Tube Well Including Supply And Use Of All Necessary Equipments And Labour As Per The Direction Of Engineer-in-charge. Supplying All Materials,labour T & P For Packing The Bore With Washed Gravel Size (p-6) Arround The Well Screen And Pipes In Good Quality Including Cost Of Gravel ,conveyance,royality,etc Complete As Per Direction Engineer-in-charge. (100m Depth) =0.786 X (0.4² - 0.2²) X 100mtr = 9.43 Say 9.5 Cum Supplying All Labour Tools ,plant And Grouting With Cement Bentonite Slurry For Saline Sealing In The Bore Arround 200mm Dia Pvc Casing Pipe Etc All Complete As Per Direction Of Engg In Charge(including Cost Of Cement And Bentonite) Labour Charges For Cutting Transverse Slot On 200 Mm Dia Pvc Pipe With Slot Size 1.5 Mm As Per Specification Threading Charges 8" Pvc Bail Plug 8" Pvc Threaded End Cap Pn-10 200mm X 12" Long Pvc Shot Piece 200mm ø Schedule 80 Casing Pipe (as Per Epm Rate Order No.2877 Dated 05.07.2025) Water Sample Test If Required
Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50mt. & Lift Of 1.5mtr Etc Complete As Per The Direction Of The Engineer-incharge. Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-incharge. Cement Concrete (1:4:8) With 4cm Size H.g.b. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&p Required Etc. Complete As Per The Direction Of The Engineer-incharge. Brick Work With Fly Ash Brick 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-incharge. Brick Work With Fly Ash Bricks 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75 Kg/cm2 With Dimensional Tolerance ±8 Percent In Cement Mortar (1:6) In Superstructure Per Cum Etc. Complete As Per The Engineer-incharge. 12mm Cement Plaster In Cement Mortar (1:6) Finished Smooth To Brick Work After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. R.c.c. Work In C.c. (1:2:4) Including Hoisting & Laying & Curring For 28 Days Using 12mm. Size Clean Black Hard Granite Crusher Broken Chips Of Approve Quality And From Approve Quarry Including Cost Taxes Conveyance Charges Of All Materials To The Worksite With Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. 2.5 Cm A.s. Flooring With C.c. (1:2:4) Using 12mm Size Black Hard Granite Crusher Broken Chips Of Approve Quality For Approve Quorry Including Water And Curring With Cost Taxes Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. "rigid Smooths Centering And Shuttering For Rcc Works Including False Work And Dismentgalling Then After Casting Including Cot Os Materials Complete. (a) Rcc Walls And Fins Including Attached Pillasters" B) Chajja/roof Slab C) Lintel D) Rcc Beams, Culumns, Grider & Bressers Etc E) Rcc Foundation An Footing Beases Of Columns Etc. Dry Brick Rammed Khoa (10 Cm) Thick Well Watered And Rammed Inluding All Cost As Per Specification In Complete. Labour Charge For M.s. Reinforcement For R.c.c. Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Still Bar (fe 415/ Fe 500) Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-incharge. White Washing 3 Coat With Approve Good Stone Lime Including Cost Conveyance Charges Of Materials Including Supply Of Labour, Gum, Indigo Etc. Required For The Work Complete As Directed By The Engineer-incharge. Finishing Wall With Water Proofing Cement Paint Of Approved Shade Two Coats To New Work To Give An Even Shade Including Cost Of Cement Paints. Etc. Complete As Per The Direction Of Engineer – In Charge. Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-incharge. Labour For Fitting And Fixing For Door And Window Etc. Complete As Per The Direction Of The Engineer-incharge. Cost Of Grill For Window Cost Of Iron Shutter For Door Priming 1 Coat With Any Appproved Primer Painting Two Coats With Approved Paint On New Work Supplying Of 160 Mm Dia Unplasticised Rigid Upvc Pipe Ivory Gray In Colour Having Specific Gravity Of 1.40 To 1.46 Gms/cc Of Straight Length Of 6 (six) Meter For Portable Water Supplies Conforming To Is - 4985 / 2000 Of Bis - Amendment - 2 Read With Table - 1 Of Is - Specification Bearing Isi Marks For Working Pressure Ci - I Upvc Pipe To Withstand Pressure Of 2.5 Kgf/sqcm & The Specification And Manufacturer Name Should Be Prominently Marked On Body Of Each Pipe As Per The Latest Amendment Of Is - 4985. It Includes The Cost Of Sockets In Case Of Plain Ended Pipe. Pdi Test ( Both Pre & Post Inspection ) Are To Be Condcuted And Should Be Marked On Body Of Each Pipe And Report Is To Be Obtained From Cipet, Bhubaneswar Necessary Approval Of Authority Including Transportation To Work Site In Complete Shape. Fitting Of Un Plasticised 160mm Dia Pvc Pipe For Following Inside Dia Mtr. For All Classes Of Pipe Including Jointing The Pipe With Solvent Cement By Non-head Application Method Including Fitting And Fixing Of Required No. Of Pvc Tee For Outlet And Pvc Shaddle And Pvc Riser Nipple For Fitting Air Valve, Equal Tee Etc. Complete Including Conveyance Pipe From Village To Worksite And Testing Of Pipe Line Etc. Complete As Per The Direction Of The Engineer-incharge. 7.5 Hp / 5.6 Kw Submersible Pumpset Corpled With Totally Enclosed Water Cooled Squirrel Case Induction Motor With Delivery Discharge 1100 Lpm At 36 Meter Head With S/s Cable, Clamp Clip Etc. Suitable For Operation At 415v + -15%, 3 Phase 50hz A.c. Power Supply As Per Particulars In Annexure. Labour Charges For Installation Of 7.5hp Motor Including Fitting & Fixing Of Base Frame, Fitting & Fixing Suction And Delivery Pipe To Motor, Nr Valve, Foot Valve, Sluice Valve And Other Fitting Materials Including Cutting, Welding And Construction Of Supporting Pillar Etc. Complete As Per The Direction Of The Engineer-incharge. 100 Mm ø Nominal Bore G.i. Pipe Having Wall Thickness 4.5 Mm Electrical Resistance Welded Of Medium Class Confirming To Is - 1239 (pt-1 Of 2004) With Socketed At One End And The Other End Protected With Plastic Thread Protector. The Socket Confirming To Is-1239 (pt-ii/1992) With Latest Amendmewnts In Random Length Of 4 To 7 Mtrs. Each Pipe Should Bear Isi Certification & Manufacturers Name / Trade Mark. 100 Mm Dia G.i. Bend Is No.1239(part-ii/1992) 100 Mm Dia G.i. Flange Is No.6392 / 1971 Cost Of Tw Safe Guard For Stand Includng Labour Charge 100mm Dia Gi Socket Is 1239 (part-ii/1992 ) Cost Of 100 Mm Dia Ms T/w Clamp Cost Of 100 Mm Dia C.i Reflux Valve(nr) 25 Mm ø Air Release Valve With Saddle & Raiser Pipe. The Air Release Valve Shall Confirm To Is 14845 With Isi Mark. 160 Mm X 160 Mm X 160 Mm ø Pvc Equal Tee (w.p. 4 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 160 Mm ø Pvc End Cap (w.p. 10 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 5/8 X3" Nut Bolt & Foundation Nut Bolt As Per Is Specification 1/8" Thick Rubber Insertion As Per Is Specification Cost, Supplying Of 160mmx160mmx110mm Dia Weldless G.i.tee (3.6mm Thickness) With Bend, Closing And Opening Arrangement Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of 160mm×110mm Dia Pvc Reducing Socket. Cost Of 12 Mm Wire Rope Control Pannel With Automatic Star Delta Starter, Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Up To 10 Hp With 16 Amp (ac -3) Duty Contractor At 415 Volt+6%-15%, 3 Phase, 50 Hz Ac Supply With Over Load Relay Range 6.00 To 9.50 Amp & No Volt Coil With Electronic Timer Suitable For Operation At Voltage Range Of 300 To 440 V. The Starter Should Provide Dependable Protection Against Over Load And Single Phasing Fitted With Volt Meter,ameter,mcb In Complete Shape Including Indicator Lamp 63 Amp Main Switch Triple Pole & Neutral Of Voltage Range 440 Volt Of Re-wirable Fuse And Shall Confirm To Is 4064 Part I & With Isi Mark. 3 X 10 Sqmm Tarpodar Cable Xlpe (cross Link Polyethylin) Conforming To Is: 7098 (part-ii) Including Laying Below .9mtr. Of The Ground And Filling The Excavated Materials Including Watering And Ramming. 2.50mm2 Submerssible (3 Core) Flat Cable Isi Mark Of Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of Wiring Of Pump Chamber Electrical Installation With Electrical Materials Such As Pvc Tape, Ampere Tape, 7/20 Pvc Copper Wire, 3/20 Pvc Copper Wire, G.i. Flexible Conduite Pipe, No.6 G.i. Wire, Copper Cable Socket, G.i. Socket And Flange And Petty Materials Required For Electrical Installation Including Fixing Of Td Cable Inside The Earth Trench As Per Direction Of Engineer-in-charge.. Electrical Earthing With Digging Earth Pit Of Size (2 Ft X 2 Ft X 3 Ft ) And Using 1/2 '' G.i Pipe ,no -6 G.i Wire ,cable Socket ,flange , Carcoal, Salt Etc. As Per The Direction Of The Engineer-incharge. 4 Kvr Power Shunt Capasitor 4.0 Mm 2 Pvc Single Core Copper Wire Labour For Drilling A Perfectly Vertical Bore Hole Of Specified Dia For A Specified Depth Below Ground Level In Alluvial Soil Strata By Mud Rotary Rig Drilling As Required To Suit The Site Condition As Per The Direction Of Engineer In Charge Including Use Of Own Rigs With Its Accessories, Tools And Plants And All Consumables (like Coir Rope, Cotton Waste And Bentonite Powder Etc. Complete) Etc. For Lowering Of Finished Bore Suitable For Lowering (minimum 400 Mm Dia.) Of 200mm Dia Gi/pvc Pipe For Housing Fitted With Sockets And With Or Without Well Screen As Per The Necessity For The Soft Medium, Hard And Boulder Formations (. Gi/pvc Casing Pipes If Required By The Contractor To Prevent Collapse Of Over Burden Portion ) Including Lower And Withdrawing Of Casing Pipes After Drilling 200mm To 450mm Dia In Over Burden Portion. For Drilling Of 200 (8”) Dia Pipe. From 0 Mtr. To 100th Meters Supply Of All Labour & T&p For Lowering The Following Sizes Of Pvc Pipes With Or Without Slotted Pipes As Per The Necessity From Ground Level & Fitted & Fixed Up In Perfectly Verticaly Position Inlcuding Cutting & Threading Pipe And Slotted Pipe And Fixing All Jointing Materials Etc. Complete. And Keeping The Top Of The Casing Pipe Threaded Including Plugging Tube Wells To Prevent Entry Of Foreign Materials From Above Excluding Cost Of Fitting & Joining Materials. 200mm Dia Pvc/gi Casing Pipes Cleaning And Developing The Production Well Using Their Own Compressor Continuously Worked Till Clear And Adequate Discharge Is Obtained From The Tube Well Including Supply And Use Of All Necessary Equipments And Labour As Per The Direction Of Engineer-in-charge. Supplying All Materials,labour T & P For Packing The Bore With Washed Gravel Size (p-6) Arround The Well Screen And Pipes In Good Quality Including Cost Of Gravel ,conveyance,royality,etc Complete As Per Direction Engineer-in-charge. (100m Depth) =0.786 X (0.4² - 0.2²) X 100mtr = 9.43 Say 9.5 Cum Supplying All Labour Tools ,plant And Grouting With Cement Bentonite Slurry For Saline Sealing In The Bore Arround 200mm Dia Pvc Casing Pipe Etc All Complete As Per Direction Of Engg In Charge(including Cost Of Cement And Bentonite) Labour Charges For Cutting Transverse Slot On 200 Mm Dia Pvc Pipe With Slot Size 1.5 Mm As Per Specification Threading Charges 8" Pvc Bail Plug 8" Pvc Threaded End Cap Pn-10 200mm X 12" Long Pvc Shot Piece 200mm ø Schedule 80 Casing Pipe (as Per Epm Rate Order No.2877 Dated 05.07.2025) Water Sample Test If Required
Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50mt. & Lift Of 1.5mtr Etc Complete As Per The Direction Of The Engineer-incharge. Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-incharge. Cement Concrete (1:4:8) With 4cm Size H.g.b. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&p Required Etc. Complete As Per The Direction Of The Engineer-incharge. Brick Work With Fly Ash Brick 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-incharge. Brick Work With Fly Ash Bricks 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75 Kg/cm2 With Dimensional Tolerance ±8 Percent In Cement Mortar (1:6) In Superstructure Per Cum Etc. Complete As Per The Engineer-incharge. 12mm Cement Plaster In Cement Mortar (1:6) Finished Smooth To Brick Work After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. R.c.c. Work In C.c. (1:2:4) Including Hoisting & Laying & Curring For 28 Days Using 12mm. Size Clean Black Hard Granite Crusher Broken Chips Of Approve Quality And From Approve Quarry Including Cost Taxes Conveyance Charges Of All Materials To The Worksite With Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. 2.5 Cm A.s. Flooring With C.c. (1:2:4) Using 12mm Size Black Hard Granite Crusher Broken Chips Of Approve Quality For Approve Quorry Including Water And Curring With Cost Taxes Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. "rigid Smooths Centering And Shuttering For Rcc Works Including False Work And Dismentgalling Then After Casting Including Cot Os Materials Complete. (a) Rcc Walls And Fins Including Attached Pillasters" B) Chajja/roof Slab C) Lintel D) Rcc Beams, Culumns, Grider & Bressers Etc E) Rcc Foundation An Footing Beases Of Columns Etc. Dry Brick Rammed Khoa (10 Cm) Thick Well Watered And Rammed Inluding All Cost As Per Specification In Complete. Labour Charge For M.s. Reinforcement For R.c.c. Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Still Bar (fe 415/ Fe 500) Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-incharge. White Washing 3 Coat With Approve Good Stone Lime Including Cost Conveyance Charges Of Materials Including Supply Of Labour, Gum, Indigo Etc. Required For The Work Complete As Directed By The Engineer-incharge. Finishing Wall With Water Proofing Cement Paint Of Approved Shade Two Coats To New Work To Give An Even Shade Including Cost Of Cement Paints. Etc. Complete As Per The Direction Of Engineer – In Charge. Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-incharge. Labour For Fitting And Fixing For Door And Window Etc. Complete As Per The Direction Of The Engineer-incharge. Cost Of Grill For Window Cost Of Iron Shutter For Door Priming 1 Coat With Any Appproved Primer Painting Two Coats With Approved Paint On New Work Supplying Of 160 Mm Dia Unplasticised Rigid Upvc Pipe Ivory Gray In Colour Having Specific Gravity Of 1.40 To 1.46 Gms/cc Of Straight Length Of 6 (six) Meter For Portable Water Supplies Conforming To Is - 4985 / 2000 Of Bis - Amendment - 2 Read With Table - 1 Of Is - Specification Bearing Isi Marks For Working Pressure Ci - I Upvc Pipe To Withstand Pressure Of 2.5 Kgf/sqcm & The Specification And Manufacturer Name Should Be Prominently Marked On Body Of Each Pipe As Per The Latest Amendment Of Is - 4985. It Includes The Cost Of Sockets In Case Of Plain Ended Pipe. Pdi Test ( Both Pre & Post Inspection ) Are To Be Condcuted And Should Be Marked On Body Of Each Pipe And Report Is To Be Obtained From Cipet, Bhubaneswar Necessary Approval Of Authority Including Transportation To Work Site In Complete Shape. Fitting Of Un Plasticised 160mm Dia Pvc Pipe For Following Inside Dia Mtr. For All Classes Of Pipe Including Jointing The Pipe With Solvent Cement By Non-head Application Method Including Fitting And Fixing Of Required No. Of Pvc Tee For Outlet And Pvc Shaddle And Pvc Riser Nipple For Fitting Air Valve, Equal Tee Etc. Complete Including Conveyance Pipe From Village To Worksite And Testing Of Pipe Line Etc. Complete As Per The Direction Of The Engineer-incharge. 7.5 Hp / 5.6 Kw Submersible Pumpset Corpled With Totally Enclosed Water Cooled Squirrel Case Induction Motor With Delivery Discharge 1100 Lpm At 36 Meter Head With S/s Cable, Clamp Clip Etc. Suitable For Operation At 415v + -15%, 3 Phase 50hz A.c. Power Supply As Per Particulars In Annexure. Labour Charges For Installation Of 7.5hp Motor Including Fitting & Fixing Of Base Frame, Fitting & Fixing Suction And Delivery Pipe To Motor, Nr Valve, Foot Valve, Sluice Valve And Other Fitting Materials Including Cutting, Welding And Construction Of Supporting Pillar Etc. Complete As Per The Direction Of The Engineer-incharge. 100 Mm ø Nominal Bore G.i. Pipe Having Wall Thickness 4.5 Mm Electrical Resistance Welded Of Medium Class Confirming To Is - 1239 (pt-1 Of 2004) With Socketed At One End And The Other End Protected With Plastic Thread Protector. The Socket Confirming To Is-1239 (pt-ii/1992) With Latest Amendmewnts In Random Length Of 4 To 7 Mtrs. Each Pipe Should Bear Isi Certification & Manufacturers Name / Trade Mark. 100 Mm Dia G.i. Bend Is No.1239(part-ii/1992) 100 Mm Dia G.i. Flange Is No.6392 / 1971 Cost Of Tw Safe Guard For Stand Includng Labour Charge 100mm Dia Gi Socket Is 1239 (part-ii/1992 ) Cost Of 100 Mm Dia Ms T/w Clamp Cost Of 100 Mm Dia C.i Reflux Valve(nr) 25 Mm ø Air Release Valve With Saddle & Raiser Pipe. The Air Release Valve Shall Confirm To Is 14845 With Isi Mark. 160 Mm X 160 Mm X 160 Mm ø Pvc Equal Tee (w.p. 4 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 160 Mm ø Pvc End Cap (w.p. 10 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 5/8 X3" Nut Bolt & Foundation Nut Bolt As Per Is Specification 1/8" Thick Rubber Insertion As Per Is Specification Cost, Supplying Of 160mmx160mmx110mm Dia Weldless G.i.tee (3.6mm Thickness) With Bend, Closing And Opening Arrangement Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of 160mm×110mm Dia Pvc Reducing Socket. Cost Of 12 Mm Wire Rope Control Pannel With Automatic Star Delta Starter, Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Up To 10 Hp With 16 Amp (ac -3) Duty Contractor At 415 Volt+6%-15%, 3 Phase, 50 Hz Ac Supply With Over Load Relay Range 6.00 To 9.50 Amp & No Volt Coil With Electronic Timer Suitable For Operation At Voltage Range Of 300 To 440 V. The Starter Should Provide Dependable Protection Against Over Load And Single Phasing Fitted With Volt Meter,ameter,mcb In Complete Shape Including Indicator Lamp 63 Amp Main Switch Triple Pole & Neutral Of Voltage Range 440 Volt Of Re-wirable Fuse And Shall Confirm To Is 4064 Part I & With Isi Mark. 3 X 10 Sqmm Tarpodar Cable Xlpe (cross Link Polyethylin) Conforming To Is: 7098 (part-ii) Including Laying Below .9mtr. Of The Ground And Filling The Excavated Materials Including Watering And Ramming. 2.50mm2 Submerssible (3 Core) Flat Cable Isi Mark Of Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of Wiring Of Pump Chamber Construction Of 3 Phase 11 Kv Line As Per Rec Standard Confirming To Ie Rules 1956 With 300 Kg 9 M Long Psc Pole With 80 Sqmm Aaac , 11 Kv "v" Cross Arm, With Required No.of 11 Kv T & C Disc. Insulators In Tension Point & 11 Kv Pin Insulators, Couping & Padding Of Poles. Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point & Double Stay At End Point With 18 Mm G.i.h.t.stay, Concreting Of Stay With Anchor Plate, Guarding At Road Crossings Etc. Including Cost Of All Materials, Labour Transportation,inspection & Commissioning Etc. Complete. Construction And Erection Of 11 /0.4 Kv , 25 Kva Double Pole Mounted Substation Star Rated Confirming To Re Rules 1956, Mounted On 2.44 Mtr. Long Structure, Supported In 300 Kg 9 Mtr Long Psc Pole,transformer Hard Channel & Top Channel Made Of 2.8 M Long 100 X 50 X 6 Mm M.s.channel, Transformer Belting On 2.80 M Long 50 X 50 X 5 Mm M.s.angle, (all Rec Spn Std.f-3) With All Accessories Like 3 Pole 11 Kv Hg Fuse(f-5)& A.b.switches(f-9) Both Mounted On 2.8 M Long 75 X 40 X 6 Mm M.s.channel And Supported By 1.0 M Long 50 X 50 X 5 Mm M.s.angle, With 3 No. 11 Kv Lightening Arrestors & Distribution Box For 25 Kva S/s, G.i.pipe Earthing With 25x5mm G.i.flats Including Cost Of 25 Kva 11/0.4 K.v.transformer , 35 Sqmm 3 1/2 Core Pvc Cable - 40 Mtr Couping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices & All Other Necessary Fittings I.e Required Size Nuts & Bolts, Brackets, Cable, Cable Sockets, Barbed Fencing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Construction Of Boundry Wall Fancing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc For Substation As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Electrical Installation With Electrical Materials Such As Pvc Tape, Ampere Tape, 7/20 Pvc Copper Wire, 3/20 Pvc Copper Wire, G.i. Flexible Conduite Pipe, No.6 G.i. Wire, Copper Cable Socket, G.i. Socket And Flange And Petty Materials Required For Electrical Installation Including Fixing Of Td Cable Inside The Earth Trench As Per Direction Of Engineer-in-charge.. Electrical Earthing With Digging Earth Pit Of Size (2 Ft X 2 Ft X 3 Ft ) And Using 1/2 '' G.i Pipe ,no -6 G.i Wire ,cable Socket ,flange , Carcoal, Salt Etc. As Per The Direction Of The Engineer-incharge. 4 Kvr Power Shunt Capasitor 4.0 Mm 2 Pvc Single Core Copper Wire Labour For Drilling A Perfectly Vertical Bore Hole Of Specified Dia For A Specified Depth Below Ground Level In Alluvial Soil Strata By Mud Rotary Rig Drilling As Required To Suit The Site Condition As Per The Direction Of Engineer In Charge Including Use Of Own Rigs With Its Accessories, Tools And Plants And All Consumables (like Coir Rope, Cotton Waste And Bentonite Powder Etc. Complete) Etc. For Lowering Of Finished Bore Suitable For Lowering (minimum 400 Mm Dia.) Of 200mm Dia Gi/pvc Pipe For Housing Fitted With Sockets And With Or Without Well Screen As Per The Necessity For The Soft Medium, Hard And Boulder Formations (. Gi/pvc Casing Pipes If Required By The Contractor To Prevent Collapse Of Over Burden Portion ) Including Lower And Withdrawing Of Casing Pipes After Drilling 200mm To 450mm Dia In Over Burden Portion. For Drilling Of 200 (8”) Dia Pipe. From 0 Mtr. To 100th Meters Supply Of All Labour & T&p For Lowering The Following Sizes Of Pvc Pipes With Or Without Slotted Pipes As Per The Necessity From Ground Level & Fitted & Fixed Up In Perfectly Verticaly Position Inlcuding Cutting & Threading Pipe And Slotted Pipe And Fixing All Jointing Materials Etc. Complete. And Keeping The Top Of The Casing Pipe Threaded Including Plugging Tube Wells To Prevent Entry Of Foreign Materials From Above Excluding Cost Of Fitting & Joining Materials. 200mm Dia Pvc/gi Casing Pipes Cleaning And Developing The Production Well Using Their Own Compressor Continuously Worked Till Clear And Adequate Discharge Is Obtained From The Tube Well Including Supply And Use Of All Necessary Equipments And Labour As Per The Direction Of Engineer-in-charge. Supplying All Materials,labour T & P For Packing The Bore With Washed Gravel Size (p-6) Arround The Well Screen And Pipes In Good Quality Including Cost Of Gravel ,conveyance,royality,etc Complete As Per Direction Engineer-in-charge. (100m Depth) =0.786 X (0.4² - 0.2²) X 100mtr = 9.43 Say 9.5 Cum Supplying All Labour Tools ,plant And Grouting With Cement Bentonite Slurry For Saline Sealing In The Bore Arround 200mm Dia Pvc Casing Pipe Etc All Complete As Per Direction Of Engg In Charge(including Cost Of Cement And Bentonite) Labour Charges For Cutting Transverse Slot On 200 Mm Dia Pvc Pipe With Slot Size 1.5 Mm As Per Specification Threading Charges 8" Pvc Bail Plug 8" Pvc Threaded End Cap Pn-10 200mm X 12" Long Pvc Shot Piece 200mm ø Schedule 80 Casing Pipe (as Per Epm Rate Order No.2877 Dated 05.07.2025) Water Sample Test If Required
Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50mt. & Lift Of 1.5mtr Etc Complete As Per The Direction Of The Engineer-incharge. Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-incharge. Cement Concrete (1:4:8) With 4cm Size H.g.b. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&p Required Etc. Complete As Per The Direction Of The Engineer-incharge. Brick Work With Fly Ash Brick 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-incharge. 12mm Cement Plaster In Cement Mortar (1:6) Finished Smooth To Brick Work After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. R.c.c. Work In C.c. (1:2:4) Including Hoisting & Laying & Curring For 28 Days Using 12mm. Size Clean Black Hard Granite Crusher Broken Chips Of Approve Quality And From Approve Quarry Including Cost Taxes Conveyance Charges Of All Materials To The Worksite With Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. "rigid Smooths Centering And Shuttering For Rcc Works Including False Work And Dismentgalling Then After Casting Including Cot Os Materials Complete. (a) Rcc Walls And Fins Including Attached Pillasters" Labour Charge For M.s. Reinforcement For R.c.c. Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Still Bar (fe 415/ Fe 500) Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-incharge. Finishing Wall With Water Proofing Cement Paint Of Approved Shade Two Coats To New Work To Give An Even Shade Including Cost Of Cement Paints. Etc. Complete As Per The Direction Of Engineer – In Charge. Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-incharge. Supplying Of 160 Mm Dia Unplasticised Rigid Upvc Pipe Ivory Gray In Colour Having Specific Gravity Of 1.40 To 1.46 Gms/cc Of Straight Length Of 6 (six) Meter For Portable Water Supplies Conforming To Is - 4985 / 2000 Of Bis - Amendment - 2 Read With Table - 1 Of Is - Specification Bearing Isi Marks For Working Pressure Ci - I Upvc Pipe To Withstand Pressure Of 2.5 Kgf/sqcm & The Specification And Manufacturer Name Should Be Prominently Marked On Body Of Each Pipe As Per The Latest Amendment Of Is - 4985. It Includes The Cost Of Sockets In Case Of Plain Ended Pipe. Pdi Test ( Both Pre & Post Inspection ) Are To Be Condcuted And Should Be Marked On Body Of Each Pipe And Report Is To Be Obtained From Cipet, Bhubaneswar Necessary Approval Of Authority Including Transportation To Work Site In Complete Shape. Fitting Of Un Plasticised 160mm Dia Pvc Pipe For Following Inside Dia Mtr. For All Classes Of Pipe Including Jointing The Pipe With Solvent Cement By Non-head Application Method Including Fitting And Fixing Of Required No. Of Pvc Tee For Outlet And Pvc Shaddle And Pvc Riser Nipple For Fitting Air Valve, Equal Tee Etc. Complete Including Conveyance Pipe From Village To Worksite And Testing Of Pipe Line Etc. Complete As Per The Direction Of The Engineer-incharge. 7.5 Hp / 5.6 Kw Submersible Pumpset Corpled With Totally Enclosed Water Cooled Squirrel Case Induction Motor With Delivery Discharge 1100 Lpm At 36 Meter Head With S/s Cable, Clamp Clip Etc. Suitable For Operation At 415v + -15%, 3 Phase 50hz A.c. Power Supply As Per Particulars In Annexure. Labour Charges For Installation Of 7.5hp Motor Including Fitting & Fixing Of Base Frame, Fitting & Fixing Suction And Delivery Pipe To Motor, Nr Valve, Foot Valve, Sluice Valve And Other Fitting Materials Including Cutting, Welding And Construction Of Supporting Pillar Etc. Complete As Per The Direction Of The Engineer-incharge. 100 Mm ø Nominal Bore G.i. Pipe Having Wall Thickness 4.5 Mm Electrical Resistance Welded Of Medium Class Confirming To Is - 1239 (pt-1 Of 2004) With Socketed At One End And The Other End Protected With Plastic Thread Protector. The Socket Confirming To Is-1239 (pt-ii/1992) With Latest Amendmewnts In Random Length Of 4 To 7 Mtrs. Each Pipe Should Bear Isi Certification & Manufacturers Name / Trade Mark. 100 Mm Dia G.i. Bend Is No.1239(part-ii/1992) 100 Mm Dia G.i. Flange Is No.6392 / 1971 100mm Dia Gi Socket Is 1239 (part-ii/1992 ) Cost Of 100 Mm Dia C.i Reflux Valve(nr) 160 Mm X 160 Mm X 160 Mm ø Pvc Equal Tee (w.p. 4 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 160 Mm ø Pvc End Cap (w.p. 10 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 5/8 X3" Nut Bolt & Foundation Nut Bolt As Per Is Specification 1/8" Thick Rubber Insertion As Per Is Specification Cost, Supplying Of 160mmx160mmx110mm Dia Weldless G.i.tee (3.6mm Thickness) With Bend, Closing And Opening Arrangement Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of 160mm×110mm Dia Pvc Reducing Socket. Cost Of 12 Mm Wire Rope Control Pannel With Automatic Star Delta Starter, Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Up To 10 Hp With 16 Amp (ac -3) Duty Contractor At 415 Volt+6%-15%, 3 Phase, 50 Hz Ac Supply With Over Load Relay Range 6.00 To 9.50 Amp & No Volt Coil With Electronic Timer Suitable For Operation At Voltage Range Of 300 To 440 V. The Starter Should Provide Dependable Protection Against Over Load And Single Phasing Fitted With Volt Meter,ameter,mcb In Complete Shape Including Indicator Lamp 63 Amp Main Switch Triple Pole & Neutral Of Voltage Range 440 Volt Of Re-wirable Fuse And Shall Confirm To Is 4064 Part I & With Isi Mark. 3 X 10 Sqmm Tarpodar Cable Xlpe (cross Link Polyethylin) Conforming To Is: 7098 (part-ii) Including Laying Below .9mtr. Of The Ground And Filling The Excavated Materials Including Watering And Ramming. Cost Of Empty Outdoor Irrigation Panel Board (size 0.45mx0.25mx1.20m) Of 18 Swg (cold Rolled) M.s. Sheet With One Coat Of Red Oxid Primer And Two Coats Of Smoke Gray / Navey Blue Enemel Paint On Both Side ( Inside & Outside) Suitable To Mount 3 Phase Star 2.50mm2 Submerssible (3 Core) Flat Cable Isi Mark Of Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Construction Of 3 Phase 11 Kv Line As Per Rec Standard Confirming To Ie Rules 1956 With 300 Kg 9 M Long Psc Pole With 80 Sqmm Aaac , 11 Kv "v" Cross Arm, With Required No.of 11 Kv T & C Disc. Insulators In Tension Point & 11 Kv Pin Insulators, Couping & Padding Of Poles. Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point & Double Stay At End Point With 18 Mm G.i.h.t.stay, Concreting Of Stay With Anchor Plate, Guarding At Road Crossings Etc. Including Cost Of All Materials, Labour Transportation,inspection & Commissioning Etc. Complete. Construction And Erection Of 11 /0.4 Kv , 25 Kva Double Pole Mounted Substation Star Rated Confirming To Re Rules 1956, Mounted On 2.44 Mtr. Long Structure, Supported In 300 Kg 9 Mtr Long Psc Pole,transformer Hard Channel & Top Channel Made Of 2.8 M Long 100 X 50 X 6 Mm M.s.channel, Transformer Belting On 2.80 M Long 50 X 50 X 5 Mm M.s.angle, (all Rec Spn Std.f-3) With All Accessories Like 3 Pole 11 Kv Hg Fuse(f-5)& A.b.switches(f-9) Both Mounted On 2.8 M Long 75 X 40 X 6 Mm M.s.channel And Supported By 1.0 M Long 50 X 50 X 5 Mm M.s.angle, With 3 No. 11 Kv Lightening Arrestors & Distribution Box For 25 Kva S/s, G.i.pipe Earthing With 25x5mm G.i.flats Including Cost Of 25 Kva 11/0.4 K.v.transformer , 35 Sqmm 3 1/2 Core Pvc Cable - 40 Mtr Couping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices & All Other Necessary Fittings I.e Required Size Nuts & Bolts, Brackets, Cable, Cable Sockets, Barbed Fencing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Construction Of Boundry Wall Fancing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc For Substation As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Electrical Installation With Electrical Materials Such As Pvc Tape, Ampere Tape, 7/20 Pvc Copper Wire, 3/20 Pvc Copper Wire, G.i. Flexible Conduite Pipe, No.6 G.i. Wire, Copper Cable Socket, G.i. Socket And Flange And Petty Materials Required For Electrical Installation Including Fixing Of Td Cable Inside The Earth Trench As Per Direction Of Engineer-in-charge.. Electrical Earthing With Digging Earth Pit Of Size (2 Ft X 2 Ft X 3 Ft ) And Using 1/2 '' G.i Pipe ,no -6 G.i Wire ,cable Socket ,flange , Carcoal, Salt Etc. As Per The Direction Of The Engineer-incharge. 4.0 Mm 2 Pvc Single Core Copper Wire
Earthwork In Excavation Of Foundation In Hard Soil Including Dressing & Levelling Of Bed Within Initial Lead Of 50mt. & Lift Of 1.5mtr Etc Complete As Per The Direction Of The Engineer-incharge. Filling In Foundation & Plinth With Sand Including Watering & Ramming Etc Complete As Per The Direction Of The Engineer-incharge. Cement Concrete (1:4:8) With 4cm Size H.g.b. Hand Broken Metal Of Approved Quality From Approved Quarry With Ramming Watering And Curring Etc. Complete Including Cost, Taxes, Royalty Convence Charge Of All Material To Worksite, Supply Of Cement T&p Required Etc. Complete As Per The Direction Of The Engineer-incharge. Brick Work With Fly Ash Brick 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75kg / Cm2 With Dimensional Tolerrance + 8% In Cement Mortar (1:6) In Foundation & Plinth Etc. Complete As Per The Engineer-incharge. Brick Work With Fly Ash Bricks 25cm X 12cm X 8cm Size Having Crushing Strength Not Less Than 75 Kg/cm2 With Dimensional Tolerance ±8 Percent In Cement Mortar (1:6) In Superstructure Per Cum Etc. Complete As Per The Engineer-incharge. 12mm Cement Plaster In Cement Mortar (1:6) Finished Smooth To Brick Work After Racking Out Joints Including Waterring And Curring With Cost, Taxes, Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. R.c.c. Work In C.c. (1:2:4) Including Hoisting & Laying & Curring For 28 Days Using 12mm. Size Clean Black Hard Granite Crusher Broken Chips Of Approve Quality And From Approve Quarry Including Cost Taxes Conveyance Charges Of All Materials To The Worksite With Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. 2.5 Cm A.s. Flooring With C.c. (1:2:4) Using 12mm Size Black Hard Granite Crusher Broken Chips Of Approve Quality For Approve Quorry Including Water And Curring With Cost Taxes Royalty And Conveyance Charges Of All Material To The Worksite And Supply Of All Labour And T&p Required For The Work Etc Complete As Directed By The Engineer-incharge. "rigid Smooths Centering And Shuttering For Rcc Works Including False Work And Dismentgalling Then After Casting Including Cot Os Materials Complete. (a) Rcc Walls And Fins Including Attached Pillasters" B) Chajja/roof Slab C) Lintel D) Rcc Beams, Culumns, Grider & Bressers Etc E) Rcc Foundation An Footing Beases Of Columns Etc. Dry Brick Rammed Khoa (10 Cm) Thick Well Watered And Rammed Inluding All Cost As Per Specification In Complete. Labour Charge For M.s. Reinforcement For R.c.c. Work Including Cutting, Bending & Typing The Grills & Placing In Position Including Cost Of Binding Wire 18 To 20 Guage Per Qntl. Including Cost Of Hysd Still Bar (fe 415/ Fe 500) Filling The Foundation And Plinth With Excavated Material As Directed By The Engineer-incharge. White Washing 3 Coat With Approve Good Stone Lime Including Cost Conveyance Charges Of Materials Including Supply Of Labour, Gum, Indigo Etc. Required For The Work Complete As Directed By The Engineer-incharge. Finishing Wall With Water Proofing Cement Paint Of Approved Shade Two Coats To New Work To Give An Even Shade Including Cost Of Cement Paints. Etc. Complete As Per The Direction Of Engineer – In Charge. Writing Charge Of Required Information And Data On Both Side Of The Transperancy Pillar Including Supplying Of Approved Paints And Required Material For Writing Etc. Complete As Per The Direction Of The Engineer-incharge. Labour For Fitting And Fixing For Door And Window Etc. Complete As Per The Direction Of The Engineer-incharge. Cost Of Grill For Window Cost Of Iron Shutter For Door Priming 1 Coat With Any Appproved Primer Painting Two Coats With Approved Paint On New Work Supplying Of 160 Mm Dia Unplasticised Rigid Upvc Pipe Ivory Gray In Colour Having Specific Gravity Of 1.40 To 1.46 Gms/cc Of Straight Length Of 6 (six) Meter For Portable Water Supplies Conforming To Is - 4985 / 2000 Of Bis - Amendment - 2 Read With Table - 1 Of Is - Specification Bearing Isi Marks For Working Pressure Ci - I Upvc Pipe To Withstand Pressure Of 2.5 Kgf/sqcm & The Specification And Manufacturer Name Should Be Prominently Marked On Body Of Each Pipe As Per The Latest Amendment Of Is - 4985. It Includes The Cost Of Sockets In Case Of Plain Ended Pipe. Pdi Test ( Both Pre & Post Inspection ) Are To Be Condcuted And Should Be Marked On Body Of Each Pipe And Report Is To Be Obtained From Cipet, Bhubaneswar Necessary Approval Of Authority Including Transportation To Work Site In Complete Shape. Fitting Of Un Plasticised 160mm Dia Pvc Pipe For Following Inside Dia Mtr. For All Classes Of Pipe Including Jointing The Pipe With Solvent Cement By Non-head Application Method Including Fitting And Fixing Of Required No. Of Pvc Tee For Outlet And Pvc Shaddle And Pvc Riser Nipple For Fitting Air Valve, Equal Tee Etc. Complete Including Conveyance Pipe From Village To Worksite And Testing Of Pipe Line Etc. Complete As Per The Direction Of The Engineer-incharge. 7.5 Hp / 5.6 Kw Submersible Pumpset Corpled With Totally Enclosed Water Cooled Squirrel Case Induction Motor With Delivery Discharge 1100 Lpm At 36 Meter Head With S/s Cable, Clamp Clip Etc. Suitable For Operation At 415v + -15%, 3 Phase 50hz A.c. Power Supply As Per Particulars In Annexure. Labour Charges For Installation Of 7.5hp Motor Including Fitting & Fixing Of Base Frame, Fitting & Fixing Suction And Delivery Pipe To Motor, Nr Valve, Foot Valve, Sluice Valve And Other Fitting Materials Including Cutting, Welding And Construction Of Supporting Pillar Etc. Complete As Per The Direction Of The Engineer-incharge. 100 Mm ø Nominal Bore G.i. Pipe Having Wall Thickness 4.5 Mm Electrical Resistance Welded Of Medium Class Confirming To Is - 1239 (pt-1 Of 2004) With Socketed At One End And The Other End Protected With Plastic Thread Protector. The Socket Confirming To Is-1239 (pt-ii/1992) With Latest Amendmewnts In Random Length Of 4 To 7 Mtrs. Each Pipe Should Bear Isi Certification & Manufacturers Name / Trade Mark. 100 Mm Dia G.i. Bend Is No.1239(part-ii/1992) 100 Mm Dia G.i. Flange Is No.6392 / 1971 Cost Of Tw Safe Guard For Stand Includng Labour Charge 100mm Dia Gi Socket Is 1239 (part-ii/1992 ) Cost Of 100 Mm Dia Ms T/w Clamp Cost Of 100 Mm Dia C.i Reflux Valve(nr) 25 Mm ø Air Release Valve With Saddle & Raiser Pipe. The Air Release Valve Shall Confirm To Is 14845 With Isi Mark. 160 Mm X 160 Mm X 160 Mm ø Pvc Equal Tee (w.p. 4 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 160 Mm ø Pvc End Cap (w.p. 10 Kgf/cm2) Confirming To Is-4995/1988 With Latest Ammendment 5/8 X3" Nut Bolt & Foundation Nut Bolt As Per Is Specification 1/8" Thick Rubber Insertion As Per Is Specification Cost, Supplying Of 160mmx160mmx110mm Dia Weldless G.i.tee (3.6mm Thickness) With Bend, Closing And Opening Arrangement Of Reputed Brand Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of 160mm×110mm Dia Pvc Reducing Socket. Cost Of 12 Mm Wire Rope Control Pannel With Automatic Star Delta Starter, Sheet Steel Enclosure Suitable For Operation Of Squirrel Cage Induction Motor Up To 10 Hp With 16 Amp (ac -3) Duty Contractor At 415 Volt+6%-15%, 3 Phase, 50 Hz Ac Supply With Over Load Relay Range 6.00 To 9.50 Amp & No Volt Coil With Electronic Timer Suitable For Operation At Voltage Range Of 300 To 440 V. The Starter Should Provide Dependable Protection Against Over Load And Single Phasing Fitted With Volt Meter,ameter,mcb In Complete Shape Including Indicator Lamp 63 Amp Main Switch Triple Pole & Neutral Of Voltage Range 440 Volt Of Re-wirable Fuse And Shall Confirm To Is 4064 Part I & With Isi Mark. 3 X 10 Sqmm Tarpodar Cable Xlpe (cross Link Polyethylin) Conforming To Is: 7098 (part-ii) Including Laying Below .9mtr. Of The Ground And Filling The Excavated Materials Including Watering And Ramming. 2.50mm2 Submerssible (3 Core) Flat Cable Isi Mark Of Reputed Brand Of Isi Specification Including All Cost, Conveyance, Cess Etc Complete But Excluding Cost Of Gst Cost Of Wiring Of Pump Chamber Construction Of 3 Phase 11 Kv Line As Per Rec Standard Confirming To Ie Rules 1956 With 300 Kg 9 M Long Psc Pole With 80 Sqmm Aaac , 11 Kv "v" Cross Arm, With Required No.of 11 Kv T & C Disc. Insulators In Tension Point & 11 Kv Pin Insulators, Couping & Padding Of Poles. Danger Board At Each Pole, Anti Climbing Devices, Stay Set At Bending Point & Double Stay At End Point With 18 Mm G.i.h.t.stay, Concreting Of Stay With Anchor Plate, Guarding At Road Crossings Etc. Including Cost Of All Materials, Labour Transportation,inspection & Commissioning Etc. Complete. Construction And Erection Of 11 /0.4 Kv , 25 Kva Double Pole Mounted Substation Star Rated Confirming To Re Rules 1956, Mounted On 2.44 Mtr. Long Structure, Supported In 300 Kg 9 Mtr Long Psc Pole,transformer Hard Channel & Top Channel Made Of 2.8 M Long 100 X 50 X 6 Mm M.s.channel, Transformer Belting On 2.80 M Long 50 X 50 X 5 Mm M.s.angle, (all Rec Spn Std.f-3) With All Accessories Like 3 Pole 11 Kv Hg Fuse(f-5)& A.b.switches(f-9) Both Mounted On 2.8 M Long 75 X 40 X 6 Mm M.s.channel And Supported By 1.0 M Long 50 X 50 X 5 Mm M.s.angle, With 3 No. 11 Kv Lightening Arrestors & Distribution Box For 25 Kva S/s, G.i.pipe Earthing With 25x5mm G.i.flats Including Cost Of 25 Kva 11/0.4 K.v.transformer , 35 Sqmm 3 1/2 Core Pvc Cable - 40 Mtr Couping & Padding Of Poles, Danger Board At Each Pole, Anti Climbing Devices & All Other Necessary Fittings I.e Required Size Nuts & Bolts, Brackets, Cable, Cable Sockets, Barbed Fencing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Construction Of Boundry Wall Fancing ( Size (15'x10') With Constn. Of Retaining Wall, Erection Of Rcc Fencing Post , Sand Filling And Metal Spreading ,fixing Of Iron Grill Gate Etc For Substation As Per Cesu Specification Etc. Including Cost Of All Materials, Labour , Transportation Complete With Liasioning For Testing Inspection & Commissioning. Electrical Installation With Electrical Materials Such As Pvc Tape, Ampere Tape, 7/20 Pvc Copper Wire, 3/20 Pvc Copper Wire, G.i. Flexible Conduite Pipe, No.6 G.i. Wire, Copper Cable Socket, G.i. Socket And Flange And Petty Materials Required For Electrical Installation Including Fixing Of Td Cable Inside The Earth Trench As Per Direction Of Engineer-in-charge.. Electrical Earthing With Digging Earth Pit Of Size (2 Ft X 2 Ft X 3 Ft ) And Using 1/2 '' G.i Pipe ,no -6 G.i Wire ,cable Socket ,flange , Carcoal, Salt Etc. As Per The Direction Of The Engineer-incharge. 4 Kvr Power Shunt Capasitor 4.0 Mm 2 Pvc Single Core Copper Wire Labour For Drilling A Perfectly Vertical Bore Hole Of Specified Dia For A Specified Depth Below Ground Level In Alluvial Soil Strata By Mud Rotary Rig Drilling As Required To Suit The Site Condition As Per The Direction Of Engineer In Charge Including Use Of Own Rigs With Its Accessories, Tools And Plants And All Consumables (like Coir Rope, Cotton Waste And Bentonite Powder Etc. Complete) Etc. For Lowering Of Finished Bore Suitable For Lowering (minimum 400 Mm Dia.) Of 200mm Dia Gi/pvc Pipe For Housing Fitted With Sockets And With Or Without Well Screen As Per The Necessity For The Soft Medium, Hard And Boulder Formations (. Gi/pvc Casing Pipes If Required By The Contractor To Prevent Collapse Of Over Burden Portion ) Including Lower And Withdrawing Of Casing Pipes After Drilling 200mm To 450mm Dia In Over Burden Portion. For Drilling Of 200 (8”) Dia Pipe. From 0 Mtr. To 100th Meters Supply Of All Labour & T&p For Lowering The Following Sizes Of Pvc Pipes With Or Without Slotted Pipes As Per The Necessity From Ground Level & Fitted & Fixed Up In Perfectly Verticaly Position Inlcuding Cutting & Threading Pipe And Slotted Pipe And Fixing All Jointing Materials Etc. Complete. And Keeping The Top Of The Casing Pipe Threaded Including Plugging Tube Wells To Prevent Entry Of Foreign Materials From Above Excluding Cost Of Fitting & Joining Materials. 200mm Dia Pvc/gi Casing Pipes Cleaning And Developing The Production Well Using Their Own Compressor Continuously Worked Till Clear And Adequate Discharge Is Obtained From The Tube Well Including Supply And Use Of All Necessary Equipments And Labour As Per The Direction Of Engineer-in-charge. Supplying All Materials,labour T & P For Packing The Bore With Washed Gravel Size (p-6) Arround The Well Screen And Pipes In Good Quality Including Cost Of Gravel ,conveyance,royality,etc Complete As Per Direction Engineer-in-charge. (100m Depth) =0.786 X (0.4² - 0.2²) X 100mtr = 9.43 Say 9.5 Cum Supplying All Labour Tools ,plant And Grouting With Cement Bentonite Slurry For Saline Sealing In The Bore Arround 200mm Dia Pvc Casing Pipe Etc All Complete As Per Direction Of Engg In Charge(including Cost Of Cement And Bentonite) Labour Charges For Cutting Transverse Slot On 200 Mm Dia Pvc Pipe With Slot Size 1.5 Mm As Per Specification Threading Charges 8" Pvc Bail Plug 8" Pvc Threaded End Cap Pn-10 200mm X 12" Long Pvc Shot Piece 200mm ø Schedule 80 Casing Pipe (as Per Epm Rate Order No.2877 Dated 05.07.2025) Water Sample Test If Required