Supply Of Sand Box Cover Gasket
Supply Of 29070259 - Sand Box Assembly For Wag-9 & Wap-7
Supply Of Swing Bolt Assembly For Sand Box As Per Clw Drg.no.1209-01.438-038 Or Latest.
Supply Of Sand Box Cover With Hinge For Wag-7 Loco As Per Clw Drg. No. 06/1/60/32.
Supply Of Elbow With Flange Of Sand Ejector Box.
Supply Of Modified Sand Box
Gem Bids For Wiring For Circuit Or Submain Wiring Of Size 2 X 15 Sq Mmand 1 X 15 Sq Mm Earth Wire Wiring For Circuit Or Submainwiring Of Size 2 X 25 Sq Mm And 1 X 25 Sq Mm Earth Wire Wiring For Circuit Or Submain Wiring Of Size 4 X 25 Sq Mmand 2 X 25 Sq Mm Earth Wire Supplying And Drawing Of 3x 15 Sq Mm Sizes Of Frls Supplying And Drawing Of 4 X15 Sq Mm Sizes Of Frls Supplying And Drawing Of 5 X 15sq Mm Sizes Of Frls Supplying And Drawing Of 6 X 15 Sqmm Sizes Of Frls Supplying And Drawing Of 3 X 25 Sq Mmsizes Of Frls Supplying And Drawing Of 6 X 25 Sq Mmsizes Of Frls Supplying And Drawing Of 3 X 4 Sq Mm Sizesof Frls Supplying And Drawing Of 6 X 4 Sq Mm Sizes Offrls Supplying And Fixing Of 20 Mm Size Of Steel Conduit Supplying And Fixing Of 25 Mm Size Of Steel Conduit Supplying And Fixing Two Module Stepped Type Electronicfan Regulator Supplying And Fixing Modular Blanking Plate Supplying And Fixing Suitable Size Gi Box With 3 Pin 5 Or 6amps Modular Socket Supplying And Fixing Suitable Size Gibox With 6 Pin 5 Or 6 And 15 Or 16 Amps Providing Andfixing Of S Type Or Fastner Type Fan Hook Supplying Andfixing Of 1 Or 2 Module 75 Mm X 75 Mm Size Or Modules Gibox Supplying And Fixing Of 3 Module 100 Mm X 75 Mmsize Or Modules Gi Box Supplying And Fixing Of 4 Module125 Mm X 75 Mm Size Or Modules Gi Box Supplying Andfixing Of 6 Module 200 Mm X 75 Mm Size Or Modules Gi Box Supplying And Fixing Of 8 Module 125 Mm X 125 Mm Sizeor Modules Gi Box Supplying And Fixing Of 12 Module 200mm X 150 Mm Size Or Modules Gi Box Supplying And Fixingof 16 Module Modules Gi Box Supplying And Fixing 5 Or 6 Aswitch Modular Supplying And Fixing 15 Or 16 A Switchmodular Supplying And Fixing 3 Pin 5 Or 6 A Socket Outletmodular Supplying And Fixing 6 Pin 15 Or 16 A Socketoutlet Modular Supplying And Fixing Modular Bell Push Bid Number Gem2025b6920715 Dated 22-11-2025 Bid Document1 52 0 0 Supplying And Fixing Dp Sheet Steel Enclosure, Providingand Testing Ding Dong Type Sound Two Module Call Bell, Dismentalling Of 1200 Mm Ceiling Fan From Hostel Rooms, Itc Of Above Existing 1200mm Ceiling Fan, Dismentallingservicing And Complete Repairing Other Than Rewinding Anditc Of 300 Mm Exhaust Fan, Dismentalling Serviceing Andrepairing Including Rewinding And Itc Of 300 Mm Exhaustfan, Dismentalling Servicing And Complete Repairing Otherthan Rewinding And Itc Of 450 Mm Exhaust Fan, Dismentalling Serviceing And Repairing Including Rewindingand Itc Of 450 Mm Exhaust Fan, Sitc Ip20 18 20 Watt Ledbatten Type Integrated Light Fixture, Supplying And Fixing Ofvertical Type 15 Litre Capacity 2000 Watt Water Storageelectric Geyser, Sitc Ip20 10 Watt Led Batten Typeintegrated Light Fixture, Installation Of Upto 2 Tr Capacitysplit Ac Units, Pdg And Fixing 1 By 4 Inch Dia Copperrefrigerant Piping, Pdg And Fixing 5 By 8 Inch Dia Copperrefrigerant Piping, Provision Of Top Up Or Additionalcharging Of R-22 Or 32 Gas, S F Suitable Size Ms Stand Forplacement Of Split Type Ac Outdoor Unit, Providing Andfixing 20 Mm Dia Heavy Duty Pvc Pipe, Sand Fsuitable Sizegi Box Wih Modular Plate And Cover In Front On Surface Or Inrecess Including Providing And Fixing 25 A Modular Socketoutlet And 25 A Modular Sp Mcb, Supplying And Fixing Of 3x 2.5 Sq Mm Pvc Insulated And Frls, Repairing Andpainting Of Existing 3 Mtr Height Galvanised Mild Steel Pole, Repairing And Painting Of Existing 7 Mtr Height Galvanisedmild Steel Pole, Supply Installation Testing Commissioningof Led Post Top Type 30 Watt With Ip 65, Sitc Of 18 Wattenergy Efficient Led Type 12 Inch Size Polycarbonate Globefittings, Sitc Of 50 Watt Energy Efficient Led Flood Lightluminaire With Inbuilt High Power Leds, Supplying Andlaying Of 63 Mm Dia Od 63 Mm And Id 51 Mm Nominal Sizedwc Hdpe Pipe, Laying And Fixing Of One Number Pvc Xlpeinsulated And Pvc Sheathed Xlpe Power Cable Of 1.1 Kvgrade Of Upto 35 Sq. Mm On Surface, Laying And Fixing Ofone Number Pvc Xlpe Insulated And Pvc Sheathed Xlpepower Cable Of 1.1 Kv Grade Of Upto 35 Sq. Mm In Pipe, Laying And Fixing Of One Number Pvc Xlpe Insulated Andpvc Sheathed Xlpe Power Cable Of 1.1 Kv Grade Of Upto 35sq. Mm In Ground, Laying And Fixing Of One Number Pvcxlpe Insulated And Pvc Sheathed Xlpe Power Cable Of 1.1kv Grade Of Upto 35 Sq. Mm In Ground Additional, Supplyingand Making End Termination With Brass Compression Glandand Aluminium Lugs For 2 X 6 Sq Mm 22mm Size, Supply Of1 No Xlpe Insulated And Pvc Sheathed Power Cable Of 1point 1 Kv Grade Of Size 2 X 6 Sqmm Aluminium Conductorarmoured Cable, Providing And Fixing 6 Swg Dia Gi Wire Onsurface Or In Recess For Loop Earthing, Supplying And Fixingdigital Weekly Programmable Time Switch Astronomicalweekly Programmable Alongwith 10 Amp 3 Pole Powercontractor, Providing Laying And Fixing 50 Mm Dia Gi Pipemedium Class In Ground Complete With Gi Fittings Includingfinishing Etc As Required, Providing Laying And Fixing 32 Mmdia Gi Pipe Medium Class In Ground Complete With Gi Fittingsincluding Finishing Etc As Required, Supply And Fixing 40mm Dia B Class Gi Pipe 500 Mm Length With 150 Mm X 150mm X 3mm Thick Ms Base Plate, Repairing Of Dust Andvermin Proof Cubical Out Door Double Door Type Floormounted, Sitc Of Self Contained Drinking Water Cooler Withnon Cfc Refrigerant Energy Efficient Compressor
Designing (aesthetically), Providing, Fabricating Package Water Treatment Plant At The Shop, Transporting To Site, Installing, Testing And Commissioning At The Site, Giving Necessary One Month's Free Test And Trail Run With Guarantee For One Year, Etc. Complete. Prefabricated Package Water Treatment Plant Comprising Following : 1) Rapid Mixing Channel In M.s. Sheets And M.s. Baffle. 2) Flocculator Not Less Than 10 Minutes Detention, In M.s. Prefabricated Box, Flocculation Being Achieved Either By Glass Pebbles Of Graded Size Or Pvc Tetrapod Or Equivalent Arrangement To Ensure Good Floc Formation. 3) Plate Or Tube Settlers Of Not Less Than 30 Minutes Detention In M.s. Prefabricated Box, The Plates / Tubes Mounted In The Settler Basin With Inclination Of Not Less Than 60 Degree To Horizontal. 4) Rapid Sand Gravity Filter In M.s.prefabricated Box With Filter Sand Not Less Than 500 Mm Thick, Supported On False Floor Below With Polypropylene Nozzles Floor Below With Polypropylene Nozzles Spaced At Not More Than 500 Mm Centres In Either Direction. 5) Backwashing, Inlet & Outlet Facilities Shall Be Provided. Air Blowers - Air Blowers Are Not Required For Wtp Having Capacity Less Than And Equal To 3 Mld, For Wtp Having Capacity More Than 3 Mld Air Blowers Capacity Of Delevering 600 Lpm Per Sqm Of Free Air Of Filter Area 0.4 Kg/sqcm At Underdrain (100% Standby) Wash Water Tank Capacity Equal To 2 % Of Designed Quantity Of Filer Water In A Day + 10 %wash Water Pump With 100 % Standby (minimum 3 Hp With All Accessories) Backwash With Water Not Less Than 0.6 Cum/sqm Of Filter Bed Area In Filter Box. Piping Of Outlet Upto Sump 6) Laboratory Equipments 7) External & Internal Electrification 8) Tcl Solution Tank With Mixing, Carrying And Dosing Arrangement With Piping. 9) Gravity Feed Gas Chlorinator With 100% Standby. 10 ) Four Alum Storage Unit 11) Drainage Arrangement 12) Providing Room With Rcc Roof For Office And Lab Space With Necessary Water Supply & Drainage Arrangement & Internal Roads 13) Rcc Sump Of One Hour Cap.and Pump House On It. 14) Internal Road 15) Wire Fencing With Gate For Wtp Premises. 16) All Civil Works For Foundation, Consisting Of Raised Rcc Platform Above G.l. Or Walls In B.b. Masonry Or Ucr Masonry Shall Be Provided As Per Needs At Site. 17) Bypass In The Form Of Pipes Or M.s. Channels Included In The Design, Effecting Bypass Of Such New Tank And Filter Individually Or Both. (limit Upto 5.0 M. From W.t.p. Face) 18) The Entire M.s. Fabricated Tank Provided With Frp Lining (5 Mm Thick) To Inside Face In Contact With Water Epoxy Painting- Two Coats With One Coat Of Primer On Outside. The Thickness Of Plates Employed Shall Not Be Less Than 6 Mm 19) Alum Dosing And Mixing Arrangements To Be Provided In Twin Tanks, Each Of 8 Hours Capacity, Capable Of Importing Does Of 20 Ppm With 5% Solution. The Alum Tanks Provided With A Dose In Steps Of 5 Ppm And Entire Unit Mounted On The Top Of Flocculator / Settler Box, In The Form Of Prefabricated Structure, With Access Platform And Ladder. Alum Boxes With Frp Lining (5 Mm Thick) Inside And Epoxy Paint Two Coats With One Coat Of Primer On Outside. 20) Both Flocculator And Settling Basins Provided With Hopper Bottom With Slope Not Less Than 45 Degrees To The Horizontal Drain Pipes And Valves Provided To Both Flocculator And Settling Basin. 21) Flow Ratings To Conform Following Parameters : A) Velocities In Channels Not To Exceed 0.6 M./second. B) Velocities In Filter Outlet Pipes And Valves Not To Exceed 1 M./second. C) Velocities In Interconnecting Pipe And Controls Not To Exceed 1m./second. D) Backwash With Air : Not Required. E) Backwash With Water : Not Less Than 0.6 M./ Sqm. Of Filter Bed Area In Filter Box. 23) Free Board For All Units Not Less Than 300 Mm 23) Rates As Above Include All Taxes, Octroi And Duties Which Would Be Specific To The Site Locations. Package Water Treatment Plant- 83 Cum/hr. (2.00 Mld)" Gadmudshingi Water Supply Scheme Tal Karveer
Gem Bids For Fire Alarm System, Hose Pipe, Brass Nozzle, Sand Bucket, Hose Box, Fire Reel Drum
Supply Of Sand Box Cover Gasket