Renewing Of 2 Nos Exhaust Fans In Station 3 And Procurement Of Spares For Starters And Exhaust Fans Installed In Tps
Replacement Of Exhaust Fans, Starters And Their Spares At Station One
Procurement Of Spares For Ht Starters Of Mine Line Make, 95 Protection Relay For Motor Insulators Complete Set Pt Fuse F 6.6Kv 7.2 Kv 3.15A Pt Epoxy 6.6Kv 3P 500Va W Lmb 110 220V Limit Switch Aux Contactor W 3No Plus 1Nc W 110V Coil Push Button Actuator With 1 No Push Button Actuator With 1 Nc Yellow Push Button Red Push Button Green Push Button Relay Negative Phs Falur Prvntn W U And O Vltg Elr Defnt Time W Cbct 110V 0 - 8A 0 - 15S Ct 50 By 5 Double Ratio Ht Power Fuse 40 Amp
Procurement On Spares Of Ht Starters For Kocp - Isolator 200 Amps 6 Point 6 Kv On Off, Isolator Fixed Contact Set, Isolator Moving Contact Set, Vaccum Contactor 400Amp 6 Point 6Kv Grade, Vacuum Contactor Rectifier Bridge, Bottle F Vcum Cntctr 400Amps 6 Point 6Kv, Vacuum Contactor Closing Coil 110V Dc, Vacuum Contactor Holding Coil 110V Dc, Auxiliary Switch For Vacuum Contactor 2N, Pt 50Va Pri 0 110V Sec 0 8 12V, Auxiliary Contactor 3No 1Nc 110V, Resin Cast P T 750 Va 6 Point 6 Kv 110V Singl, P T Resin Cast300va 6 Point 6 Kv 110V 3P, Ht Control Fuse 6 Point 6Kv 2Amp, Ct Resin Cast Mldd 100 By 5 6 Point 6Kv F O L S C, Dmdc Mldd 6 Point 6 Kv Insltrf I C T G O Gfuse, Earth Leakage Relay Unit Complete Witho, O L Rly Thrml 4 To 7Point 5 Ct Oprtd W Mntng, 72Sq Mm Ammeter 0 150 By 450A, Voltmeter 72Mm2 0 To 10Kv By 110V 6 Point 6Kv 110V, Ammeter Selector Switch, Hrc Fuse Base And Carrier For Control, Hrc Fuse Link For Control, Push Button With Element For Start Sto, Lamp Holder With Lamp On Off Trip, Isolator Limit Switch, Single Phasing Preventor With Module, Diode By 255 For Vacuum Contactor
Procurement Of Spares Of Ht Starters For Bwocp Mahalaxmi Area, 115 Isolator 200 Amps 6 Point 6 Kv On Off Isolator Fixed Contact Set Isolator Moving Contact Set Vaccum Contactor 400Amp 6 Point 6Kv Grade Vacuum Contactor Rectifier Bridge Bottle F Vcum Cntctr 400Amps 6 Point 6Kv Vacuum Contactor Closing Coil 110V Dc Auxiliary Switch For Vacuum Contactor 2N Pt 50Va Pri 0 110V Sec 0 8 12V Ht Control Fuse 6 Point 6Kv 2Amp Resin Cast P T 750 Va 6 Point 6 Kv 110V Singl Resin Cast Moulded Cbct 6 Point 6Kv Ct Resin Cast Mldd 100 By 5 6 Point 6Kv F O L S C Ct Resin Cast Mldd 150 By 5 6 Point 6Kv F O L S C Earth Leakage Relay Unit Complete Witho Static Type Idmtl Over Current And Short 72Sq Mm Ammeter 0 150 By 450A Voltmeter 72Mm2 0 To 10Kv By 110V 6 Point 6Kv 110V Hrc Fuse Base And Carrier For Control Push Button With Element For Start Sto Lamp Holder With Lamp On Off Trip Power Hrc Fuse Brass Cable Gland Complete With C I Clam Single Phasing Preventor With Module
Procurement Of Spares Of Self-Starters And Alternators Fitted In Diesel Operated Hemms Dumpers, Dozers, Drills, Etc.
Supply of Spares Of Starters Main Switch Board Power Supply Unit And Engine Da Alarm Panel 22Bslc001, 809 Es3439b-3Tf31100au0 2No 2Nc Apl Es3439b- 3Wx36321jk00 Es3439b-3Sb52356he10 Es3439b- 3Tf34000ar0 2No 2Nc Es3439b-3Ua50001e 3Ux1418 Es3439b-3Ua50001g 3Ux1418 Es3439b-3Tf52020af0 Es3439b-3Nwns6 Es3439b-3Sb5286-6Hc12 Es3439b- 3Ua12-08-Oak Es3439b-3Ua12-08-Oal Es3439b-K22615 Es3439b-3Rp15761nm20 Es3439b-3Tf32000af0 No Nc Es3439b-3Th30220au0 Es3439b-3Ua50001e Es3439b- 3Ua5800-2Ez1
Repairing, Replacement Of Old Damaged Cables, Mccb, Starters, And Other Spares In Pump House I And Ii Repairs To Panel
Repairing, Replacement Of Old Damaged Cables, Mccb, Starters, And Other Spares In Pump House I, Ii
Repairing, Replacement Of Old Damaged Cables, Mccb, Starters, And Other Spares In Pump House I And Ii Repairs To Panel