Supply Of Supply Of 160 Kva, 11/0.416 Kv, 3 Phase, 50 Hz, Outdoor Type Distribution Transformer Complete, Onan Cooled, Delta/star Dyn 11 Group, Copper Wound, Plinth Mounted Transformer With First Fill Of Transformer Oil And With Standard Fittings Conforming To Is:1180 Part-1/2014 Latest, Energy Efficiency: Level 2 Of Table 3 Of Amendment No.4 March 2021 Details As Per Enclosed Annexure..
Providing Cable Duct, Culvert, Transformer Structural Plinth, Retaining Wall, Metal Spreading, Filling The Site With Gravel And All Allied Civil Works For The Proposed New Nathamedu 110/ 22 Kv Ss Tp1-160/2025-26
Construction Of Cable Duct, Culvert, Transformer Structural Plinth, Retaining Wall, Metal Spreading, Filling The Site With Gravel And All Allied Civil Works For The Proposed New Ranganoor 110/22 Kv Ss. Tp1-158/2025-26
Supply Of Supply Of Outdoor Type, Plinth Mounted, Distribution Transformer, Minimum Energy Efficiency Level 3 Of Rating 250 Kva, 3-phase, 11kv/415-240v, 50hz, Oil Immersed, Non Sealed Type Transformer Tank Body And Cover Are Bolted, Copper Wound, Primary Winding In Delta And Secondary Winding In Star Vector Symbol- Dyn11, Onan Cooled Transformer, Conforming To Is 1180 Part1:2014 With Amendment Nos. 1, 2, 3, 4 Or Latest, And Supplied With All Standard Fittings Mentioned In Clause 20.1 Of Is 1180 Part 1 Latest With Condition That Drain-cum-sampling Valve. Oil Temperature Indicator & Winding Temperature Indicators Will Be Provided As Per Clause 20.2 F Of Is 1180 Part 1. Terminal Arrangement: The Transformers Shall Be Fitted On High Voltage And Low Voltage Sides Bushing Appropriate Voltage And Current Ratings., Low Voltage Side Cable End Box Required . The High Voltage Bushings 3 Nos. Shall Conform To Is/ Iec 60137. The Low Voltage Bushings 4 Nos. Shall Conform To Is 7421. Off-circuit Tap Changer Applicable For All Ratings Above 200 Kva For Variation Of Hv Voltage From +5% To -10% In Steps Of 2.5%. Following Has To Be Submitted By Supplier Along With Supply Of Material: I Type Test Report Of Transformer Having Same Rating, Make & Model If Any And Design From Nabl Accredited Lab As Per Is: 1180 Part 1 Latest. Ii Routine Test Certificates As Per Is: 1180 Part 1 Latest. Iii Special Test Certificates As Per Clause 21.4 Sl. No. A, C, D & E Of Is:1180 Part 1 Latest..
Construction Of Transformer Plinth, Vcb, Ct, Cable Box Support Structure, Cable Trench, Circular Loop And Other Allied Work At Baishnabnagar 33/11 Kv Sub-Station Under Malda Division, In The District Of Malda
Providing Transformer Plinth Of Various Transformer Centers By Providing And Fixing Rcc Plinth As Per Drawing Including Material Carting At Various Transformer At Various Location Of Jurisdiction Of Bhilad Sub Division Under Vapi Industrial Division
Providing Plinth For Ah Tower, Vc, Wc Structure, Equipment And Transformer Plinth, Supply And Erection Of Ah Tower With Boom And Allied Civil Works For Enhancement Of Existing Auto Transformer Capacity At Existing Kurukkathi 230Kv Ss
Construction Of Control Room Building , Providing Foundation Concrete Structure, Equipment Plinth, Plinth For Breaker, Transformer Plinth, Cable Duct And Other Civil Related Works For The Establishment Of 110 Kv Ss At Edaicode
Invitation Of Quotation For Work Of Rising Of Plinth Of Various Transformer Location For Tankal, Gandevi S/Dn Under Jurisdiction Navsari Rural Division.
Invitation Of Quotation For Work Of Rising Of Plinth Of Various Transformer Location For Eroo, Amalsad S/Dn Under Jurisdiction Navsari Rural Division.